Environmental and safety sensor node for toy haulers, RVs, and similar enclosed living spaces. Measures temperature, humidity, real CO2, VOC index, carbon monoxide, and propane / LPG levels, then broadcasts readings over a CAN bus. Supports over-the-air (OTA) firmware updates, WiFi credential provisioning via CAN, and network discovery for integration with TrailCurrent Headwaters.
- MCU board: Waveshare ESP32-S3-RS485-CAN
- ESP32-S3R8 (8MB PSRAM, external 16MB flash)
- Built-in isolated CAN transceiver (TJA1051) on GPIO15/16
- Built-in isolated RS485 transceiver (unused by Borealis)
- External PCF85063AT RTC
- 7-36V DC input or 5V USB-C
- CO2 / temp / humidity: DFRobot SEN0536 (Sensirion SCD41, photoacoustic NDIR)
- VOC trending: DFRobot SEN0394 (Sensirion SGP40, VOC Index 1-500)
- Carbon monoxide: DFRobot SEN0466 (factory-calibrated electrochemical, 0-1000 ppm)
- Propane / LPG: DFRobot SEN0131 (MQ-6 with adjustable potentiometer)
| GPIO | Function |
|---|---|
| 5 | I2C SDA (SCD41, SGP40, SEN0466) |
| 6 | I2C SCL (SCD41, SGP40, SEN0466) |
| 3 | MQ-6 analog input (ADC1_CH2, via 10k/15k divider) |
| 15 | CAN TX (internal transceiver) |
| 16 | CAN RX (internal transceiver) |
See DOCS/sensor-wiring.md for full wiring details and the ribbon-cable diagram. When the parts arrive, work through DOCS/arrival-todos.md for the assembly, calibration, and validation checklist.
- KiCad schematic and PCB files are in the
EDA/directory - The MQ-6 sensor's analog output swings 0-5V; a 10kΩ + 15kΩ resistor divider scales it to 0-3V at the ADC pin
- Add a 100nF cap from the ADC pin to GND for noise filtering near the heater
This project uses ESP-IDF (v5.x).
# Configure (first time only)
idf.py set-target esp32s3
# Build
idf.py build
# Flash via USB
idf.py flash
# Monitor serial output
idf.py monitor
# Build, flash, and monitor in one step
idf.py build flash monitorcurl -X POST http://<hostname>.local/ota --data-binary @build/borealis.bin| File | Purpose |
|---|---|
main/main.c |
Sensor reading loop, TWAI task, CAN frame transmission |
main/sensors.c/h |
I²C drivers for SCD41, SGP40, SEN0466; ADC reading and Rs/R0 calculation for MQ-6 |
main/wifi_config.c/h |
NVS-backed WiFi credentials and STA connect/disconnect |
main/ota.c/h |
HTTP POST /ota server, runs in dedicated task |
main/discovery.c/h |
mDNS-based network discovery for Headwaters registration |
The TWAI (CAN) driver runs in a dedicated FreeRTOS task with alert-based message handling. It uses a dual-state transmission model:
- TX_ACTIVE (1000 ms period): Normal operation when peers are detected on the bus
- TX_PROBING (2000 ms period): Slow probe when no peers are ACKing, reduces bus noise
The task automatically transitions between states based on TX success/failure and incoming messages. Bus-off recovery is handled via TWAI alerts. This pattern is shared with all other TrailCurrent ESP-IDF modules — see TrailCurrentReservoir, TrailCurrentSwitchback, etc.
All communication uses a 500 kbps CAN bus. The device transmits sensor data and receives OTA / WiFi / discovery commands.
CAN ID: 0x1F | DLC: 8 | Period: 1000 ms
| Byte | Content |
|---|---|
| 0 | Temperature (°C, signed int8, rounded) |
| 1 | Temperature (°F, signed int8, rounded) |
| 2-3 | Humidity (big-endian uint16, value × 100, e.g. 4523 = 45.23%) |
| 4-5 | Real CO2 in ppm (big-endian uint16, NDIR measurement from SCD41) |
| 6-7 | VOC Index (big-endian uint16, range 1-500, baseline ≈ 100) |
CAN ID: 0x20 | DLC: 8 | Period: 1000 ms
| Byte | Content |
|---|---|
| 0-1 | CO concentration in ppm (big-endian uint16) |
| 2-3 | LPG / propane Rs/R0 ratio × 1000 (big-endian uint16; lower = more gas) |
| 4 | Alarm flags (bitmask) |
| 5-7 | Reserved |
Alarm flag bits:
0x01CO warning (≥ 70 ppm)0x02CO alarm (≥ 200 ppm)0x04LPG warning (Rs/R0 < 0.5)0x08LPG alarm (Rs/R0 < 0.3)0x10CO2 warning (≥ 1500 ppm)0x20CO2 alarm (≥ 2500 ppm)0x40VOC alarm (Index ≥ 400)
CAN ID: 0x00 | DLC: 3+
| Byte | Content |
|---|---|
| 0-2 | Target MAC suffix (e.g., F2 7E 6C for hostname esp32-F27E6C) |
When the MAC matches, the device connects to its configured WiFi network, starts an HTTP server at /ota, and waits for a firmware upload for 3 minutes before returning to normal operation.
CAN ID: 0x01 | DLC: varies
WiFi credentials are provisioned over CAN using a chunked protocol. Credentials are stored in NVS (non-volatile storage) and persist across reboots.
| Byte 0 | Message Type |
|---|---|
0x01 |
Start: contains SSID length, password length, chunk counts |
0x02 |
SSID chunk: 6-byte payload with chunk index |
0x03 |
Password chunk: 6-byte payload with chunk index |
0x04 |
End: contains XOR checksum for validation |
The protocol includes a 5-second timeout — if chunks stop arriving, the state resets.
CAN ID: 0x02 | DLC: any (broadcast)
When received, the device connects to WiFi and advertises itself via mDNS (_trailcurrent._tcp) with TXT records:
| Key | Value |
|---|---|
type |
borealis |
canid |
0x1F |
fw |
firmware version |
Headwaters confirms registration by calling GET /discovery/confirm. The discovery window is 3 minutes.
CAN ID: 0x04 | DLC: 6
Sent once on boot after CAN initialization, then again whenever a peer is first detected. Reports the running firmware version so Headwaters can track what each device is running.
| Byte | Content |
|---|---|
| 0-2 | Last 3 bytes of device WiFi MAC (matches hostname esp32-XXYYZZ) |
| 3 | Version major |
| 4 | Version minor |
| 5 | Version patch |
| ppm | Level |
|---|---|
| < 800 | Fresh / well-ventilated |
| 800-1499 | Normal indoor |
| 1500-2499 | Stuffy / drowsiness possible |
| ≥ 2500 | Alarm |
| Index | Meaning |
|---|---|
| 1-99 | Better than recent baseline |
| 100 | Typical indoor air (24-hour running average) |
| 101-249 | Worse than baseline |
| 250-399 | Significant pollution event |
| 400-500 | Severe pollution event |
| ppm | Level |
|---|---|
| < 35 | Normal |
| 35-69 | Elevated |
| 70-199 | Warning |
| ≥ 200 | Alarm |
| Rs/R0 | Level |
|---|---|
| > 0.7 | Clean air |
| 0.5-0.7 | Trace |
| 0.3-0.5 | Warning |
| < 0.3 | Alarm |
The MQ-6 outputs a resistance ratio rather than ppm; calibrating to absolute ppm requires tank-test exposure. For leak detection the ratio is what matters: a sharp drop from baseline indicates propane present.
- Provision WiFi credentials via CAN (one-time setup, stored in NVS)
- Send an OTA trigger message on CAN ID
0x00with the target device's MAC suffix - The device connects to WiFi
- Upload firmware via HTTP:
curl -X POST http://<hostname>.local/ota --data-binary @build/borealis.bin - On success, the device reboots with new firmware
- On timeout (3 minutes), the device disconnects WiFi and resumes normal operation
The device hostname is printed to serial at boot (format: esp32-XXYYZZ).