Skip to content

About

A repository for the EDA, CAD and firmware to make a TrailCurrent Borealis module which provides air quality data

Resources

Contributing

Stars

0 stars

Watchers

0 watching

Forks

Repository files navigation

TrailCurrent Borealis

TrailCurrent Borealis

Environmental and safety sensor node for toy haulers, RVs, and similar enclosed living spaces. Measures temperature, humidity, real CO2, VOC index, carbon monoxide, and propane / LPG levels, then broadcasts readings over a CAN bus. Supports over-the-air (OTA) firmware updates, WiFi credential provisioning via CAN, and network discovery for integration with TrailCurrent Headwaters.

Hardware

  • MCU board: Waveshare ESP32-S3-RS485-CAN
    • ESP32-S3R8 (8MB PSRAM, external 16MB flash)
    • Built-in isolated CAN transceiver (TJA1051) on GPIO15/16
    • Built-in isolated RS485 transceiver (unused by Borealis)
    • External PCF85063AT RTC
    • 7-36V DC input or 5V USB-C
  • CO2 / temp / humidity: DFRobot SEN0536 (Sensirion SCD41, photoacoustic NDIR)
  • VOC trending: DFRobot SEN0394 (Sensirion SGP40, VOC Index 1-500)
  • Carbon monoxide: DFRobot SEN0466 (factory-calibrated electrochemical, 0-1000 ppm)
  • Propane / LPG: DFRobot SEN0131 (MQ-6 with adjustable potentiometer)

Pin Assignments

GPIO Function
5 I2C SDA (SCD41, SGP40, SEN0466)
6 I2C SCL (SCD41, SGP40, SEN0466)
3 MQ-6 analog input (ADC1_CH2, via 10k/15k divider)
15 CAN TX (internal transceiver)
16 CAN RX (internal transceiver)

See DOCS/sensor-wiring.md for full wiring details and the ribbon-cable diagram. When the parts arrive, work through DOCS/arrival-todos.md for the assembly, calibration, and validation checklist.

Circuit Notes

  • KiCad schematic and PCB files are in the EDA/ directory
  • The MQ-6 sensor's analog output swings 0-5V; a 10kΩ + 15kΩ resistor divider scales it to 0-3V at the ADC pin
  • Add a 100nF cap from the ADC pin to GND for noise filtering near the heater

Building

This project uses ESP-IDF (v5.x).

# Configure (first time only)
idf.py set-target esp32s3

# Build
idf.py build

# Flash via USB
idf.py flash

# Monitor serial output
idf.py monitor

# Build, flash, and monitor in one step
idf.py build flash monitor

OTA Upload

curl -X POST http://<hostname>.local/ota --data-binary @build/borealis.bin

Architecture

File Purpose
main/main.c Sensor reading loop, TWAI task, CAN frame transmission
main/sensors.c/h I²C drivers for SCD41, SGP40, SEN0466; ADC reading and Rs/R0 calculation for MQ-6
main/wifi_config.c/h NVS-backed WiFi credentials and STA connect/disconnect
main/ota.c/h HTTP POST /ota server, runs in dedicated task
main/discovery.c/h mDNS-based network discovery for Headwaters registration

CAN Bus Task

The TWAI (CAN) driver runs in a dedicated FreeRTOS task with alert-based message handling. It uses a dual-state transmission model:

  • TX_ACTIVE (1000 ms period): Normal operation when peers are detected on the bus
  • TX_PROBING (2000 ms period): Slow probe when no peers are ACKing, reduces bus noise

The task automatically transitions between states based on TX success/failure and incoming messages. Bus-off recovery is handled via TWAI alerts. This pattern is shared with all other TrailCurrent ESP-IDF modules — see TrailCurrentReservoir, TrailCurrentSwitchback, etc.

CAN Bus Protocol

All communication uses a 500 kbps CAN bus. The device transmits sensor data and receives OTA / WiFi / discovery commands.

Environmental Data (TX)

CAN ID: 0x1F | DLC: 8 | Period: 1000 ms

Byte Content
0 Temperature (°C, signed int8, rounded)
1 Temperature (°F, signed int8, rounded)
2-3 Humidity (big-endian uint16, value × 100, e.g. 4523 = 45.23%)
4-5 Real CO2 in ppm (big-endian uint16, NDIR measurement from SCD41)
6-7 VOC Index (big-endian uint16, range 1-500, baseline ≈ 100)

Safety Data (TX)

CAN ID: 0x20 | DLC: 8 | Period: 1000 ms

Byte Content
0-1 CO concentration in ppm (big-endian uint16)
2-3 LPG / propane Rs/R0 ratio × 1000 (big-endian uint16; lower = more gas)
4 Alarm flags (bitmask)
5-7 Reserved

Alarm flag bits:

  • 0x01 CO warning (≥ 70 ppm)
  • 0x02 CO alarm (≥ 200 ppm)
  • 0x04 LPG warning (Rs/R0 < 0.5)
  • 0x08 LPG alarm (Rs/R0 < 0.3)
  • 0x10 CO2 warning (≥ 1500 ppm)
  • 0x20 CO2 alarm (≥ 2500 ppm)
  • 0x40 VOC alarm (Index ≥ 400)

OTA Trigger (RX)

CAN ID: 0x00 | DLC: 3+

Byte Content
0-2 Target MAC suffix (e.g., F2 7E 6C for hostname esp32-F27E6C)

When the MAC matches, the device connects to its configured WiFi network, starts an HTTP server at /ota, and waits for a firmware upload for 3 minutes before returning to normal operation.

WiFi Configuration (RX)

CAN ID: 0x01 | DLC: varies

WiFi credentials are provisioned over CAN using a chunked protocol. Credentials are stored in NVS (non-volatile storage) and persist across reboots.

Byte 0 Message Type
0x01 Start: contains SSID length, password length, chunk counts
0x02 SSID chunk: 6-byte payload with chunk index
0x03 Password chunk: 6-byte payload with chunk index
0x04 End: contains XOR checksum for validation

The protocol includes a 5-second timeout — if chunks stop arriving, the state resets.

Discovery Trigger (RX)

CAN ID: 0x02 | DLC: any (broadcast)

When received, the device connects to WiFi and advertises itself via mDNS (_trailcurrent._tcp) with TXT records:

Key Value
type borealis
canid 0x1F
fw firmware version

Headwaters confirms registration by calling GET /discovery/confirm. The discovery window is 3 minutes.

Firmware Version Report (TX)

CAN ID: 0x04 | DLC: 6

Sent once on boot after CAN initialization, then again whenever a peer is first detected. Reports the running firmware version so Headwaters can track what each device is running.

Byte Content
0-2 Last 3 bytes of device WiFi MAC (matches hostname esp32-XXYYZZ)
3 Version major
4 Version minor
5 Version patch

Air Quality and Safety Thresholds

Real CO2 (SCD41, NDIR)

ppm Level
< 800 Fresh / well-ventilated
800-1499 Normal indoor
1500-2499 Stuffy / drowsiness possible
≥ 2500 Alarm

VOC Index (SGP40)

Index Meaning
1-99 Better than recent baseline
100 Typical indoor air (24-hour running average)
101-249 Worse than baseline
250-399 Significant pollution event
400-500 Severe pollution event

Carbon Monoxide (SEN0466)

ppm Level
< 35 Normal
35-69 Elevated
70-199 Warning
≥ 200 Alarm

Propane / LPG (MQ-6, Rs/R0 ratio)

Rs/R0 Level
> 0.7 Clean air
0.5-0.7 Trace
0.3-0.5 Warning
< 0.3 Alarm

The MQ-6 outputs a resistance ratio rather than ppm; calibrating to absolute ppm requires tank-test exposure. For leak detection the ratio is what matters: a sharp drop from baseline indicates propane present.

OTA Updates

  1. Provision WiFi credentials via CAN (one-time setup, stored in NVS)
  2. Send an OTA trigger message on CAN ID 0x00 with the target device's MAC suffix
  3. The device connects to WiFi
  4. Upload firmware via HTTP: curl -X POST http://<hostname>.local/ota --data-binary @build/borealis.bin
  5. On success, the device reboots with new firmware
  6. On timeout (3 minutes), the device disconnects WiFi and resumes normal operation

The device hostname is printed to serial at boot (format: esp32-XXYYZZ).

License

MIT

About

A repository for the EDA, CAD and firmware to make a TrailCurrent Borealis module which provides air quality data

Resources

Contributing

Stars

0 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages