fix(drivers): bundle zap 3.1.2, a Zap on firmware 7.x reads as the site meter again - #1961

Merged
frahlg merged 1 commit into
masterfrom
fix/bundle-zap-3.1.2
Nov 4, 2026
Merged

frahlg merged 1 commit into
masterfrom
fix/bundle-zap-3.1.2

Conversation

@davmoz

@davmoz davmoz commented Nov 4, 2026 •

Copy link
Copy Markdown
Member

Problem

A Zap that updates to firmware 7.x serves its local API in data model v2. zap 3.1.1 read only the old names (W, L1_V), so FTW got no power reading from the Zap and lost its site meter. An owner reported it after a Zap got the new firmware. Zaps are being updated now.

Change

Tested

  • go test ./internal/drivers/ -run Zap and ./internal/fleetping/ pass. The new tests fail against 3.1.1.
  • scripts/sync-bundled-drivers.sh --check and --behind pass.
  • On real Zaps on 7.0.3, through FTW's Lua host, GET only:
    • Zap-HAN with a real meter, 3.1.1: no meter, site-meter payload unavailable. This reproduces the report.
    • Zap-HAN with a real meter, 3.1.2: meter reads, with phase V/A/W and energy totals.
    • Zap-P1 with a simulated Solis (a Modbus simulator on the LAN), 3.1.2: the Solis meter DER reads, export negative. The firmware and its payload are real; the inverter is not.
  • 7.x signs phase current with its power. phaseCurrentsA and fuse_phase.go take the absolute value, so fuse handling is unchanged. The Home Assistant bridge publishes the value as it is, so phase_1_a is negative during export on 7.x.

Not run on a full FTW site, and not tested on a Zap on older firmware. For the old names, the unit tests cover that path.

Not covered

read_pv and read_battery on a Zap with firmware 7.x still read nothing. That follows in device-drivers and a new pin bump (srcfl/device-drivers#170).

🤖 Generated with Claude Code

…te meter again

Moves the pin to srcfl/device-drivers@d662c3eb (#208). Only the Zap driver
changes. A Zap on firmware 7.x serves its local API in data model v2, and
zap 3.1.1 read only the old names, so FTW lost its site meter.

The new tests use the payload a Zap-HAN on 7.0.3 sent, and they fail against
3.1.1. read_pv and read_battery on 7.x are not covered yet.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Signed-off-by: David Mozart <dmozartandraws@gmail.com>
@frahlg
frahlg merged commit 7210076 into master Nov 4, 2026
22 of 23 checks passed