Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Portal datasets may contain multiple points for the same field or different SoC candidates. index_points previously kept the last row per key/name and lookup chose the greatest row number, allowing an older measurement to hide a newer one.
Both stages now compare parsed measurement timestamps, including timezone offsets and fractional seconds. Valid timestamps outrank missing or invalid ones; equal or unavailable timestamps retain row-order fallback. Bumps vag_vehicle to 0.3.1 and refreshes generated metadata.
Adds diagnostics once per newly downloaded dataset: VIN-masked filename, portal fetch time, candidate count, selected row and selection reason. Logs up to 32 SoC candidate rows (including those discarded by indexing), with key/name, value, timestamp and selection flag; excess rows are counted. No raw datasets or credentials are logged. This distinguishes stale upstream measurements from incorrect local selection.
Validation:
No credentials, VINs or raw site datasets are included. This does not refresh stale upstream data. After merge, FTW must advance its bundled-driver source pin and regenerate its recovery snapshot to reach bundled installations.