12 changes: 12 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,18 @@

## [Unreleased]

### saj-emanager 0.1.2

The NovaCore device-support registry accepts this driver.

- `host.set_make` is the brand key `saj`. `SAJ` is not a key in `/brands`.
Same correction the SAJ H2 driver took in 1.0.2.
- `host.emit_metric` is not a host function in that registry. Device count
and the phase-scale divisor are one log line each. Inverter, load,
generator, raw capacity, and the FeedIn/Sell counters are not published:
the first three have no stated sign, capacity is not a known Wh unit, and
FeedIn versus Sell is still an open direction question.

### saj-emanager 0.1.1

Emitted power uses the same signs as the other drivers. Generation is
Expand Down
4 changes: 2 additions & 2 deletions SUPPORT_STATUS.md
Original file line number Diff line number Diff line change
Expand Up @@ -120,8 +120,8 @@ Catalog source is not proof that a target can install or run a driver.
| pixii_pv | 0.3.3 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| remne_p1ib | 0.1.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| remne_p1ib | 0.1.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| saj-emanager | 0.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| saj-emanager | 0.1.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| saj-emanager | 0.1.2 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| saj-emanager | 0.1.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| saj | 1.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| saj | 1.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| schneider_meter | 1.0.5 | ftw-core | not_assessed | — | not_recorded | not_assessed |
Expand Down
2 changes: 1 addition & 1 deletion devices.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -1104,7 +1104,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "saj-emanager"
version: "0.1.1"
version: "0.1.2"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
Expand Down
66 changes: 25 additions & 41 deletions drivers/lua/saj-emanager.lua
Original file line number Diff line number Diff line change
Expand Up @@ -79,9 +79,9 @@
-- CH2's own map does not trust the power word; it uses direction registers
-- this sheet does not have.
--
-- Load (0x8493), inverter (0x848D) and generator (0x8498) power are int32
-- with no stated sign. They are metrics named *_vendor and are not DER
-- fields, so a positive word there is not a site-signed watt.
-- Load (0x8493), inverter (0x848D) and generator (0x8498) are int32 with
-- no stated sign. They are left unpublished: a DER field would invent a
-- sign, and the NovaCore registry host does not provide emit_metric.
--
-- ═══ Voltage and frequency may be summed — the sheet does not say so ═════
--
Expand Down Expand Up @@ -113,15 +113,15 @@
-- in 0.01%..100.00%, or battery power is non-zero. A real 0% pack that still
-- reports capacity is emitted, SoC and all.
--
-- The capacity unit on the sheet is "K", not kWh and not Wh. The raw word
-- is a presence signal and a metric. It is not converted.
-- The capacity unit on the sheet is "K", not kWh and not Wh. A non-zero
-- word means a pack is present. It is not converted and not published.
--
-- ═══ Energy direction ═════════════════════════════════════════════════════
--
-- PV generation, battery charge and battery discharge totals are named on
-- the sheet and are copied onto the DER. FeedIn (0x852E) and Sell (0x8536)
-- are not: SAJ uses both words for both directions in different PDFs. They
-- are metrics under the vendor names, not meter import/export.
-- are not published: SAJ uses both words for both directions in different
-- PDFs, so neither is meter import or export.
--
-- ═══ Control 0x8400-0x8405 — NOT IMPLEMENTED ══════════════════════════════
--
Expand Down Expand Up @@ -164,7 +164,7 @@ DRIVER = {
id = "saj-emanager",
name = "SAJ eManager C1 Pro",
manufacturer = "SAJ",
version = "0.1.1",
version = "0.1.2",
host_api_min = 1,
host_api_max = 1,
protocols = { "modbus" },
Expand Down Expand Up @@ -222,8 +222,6 @@ local ENERGY_WORDS = 80
local PAIR_TOTAL_PV = 3 -- 0x8506
local PAIR_TOTAL_BAT_CHG = 7 -- 0x850E
local PAIR_TOTAL_BAT_DIS = 11 -- 0x8516
local PAIR_TOTAL_FEED_IN = 23 -- 0x852E
local PAIR_TOTAL_SELL = 27 -- 0x8536

-- MPVMode 5 is "Fault" on the sheet.
local MODE_FAULT = 5
Expand Down Expand Up @@ -333,6 +331,7 @@ end
local GIVE_UP_AFTER = 3
local read_failures = {}
local announced = false
local scale_logged = false

local function complete(regs, count)
if regs == nil then return false end
Expand Down Expand Up @@ -420,16 +419,25 @@ end
local function note_identity(device_count, devices)
local sn = first_sn(devices)
if sn then host.set_sn(sn) end
if device_count ~= nil then
host.emit_metric("saj_emanager_device_count", device_count)
end
if announced or device_count == nil then return end
announced = true
host.log("info", string.format(
"SAJ eManager: DeviceNum=%d first SN=%s",
device_count, sn or "(none)"))
end

-- One line, once. The registry host has no emit_metric, and the voltage
-- check at Castellum needs to see whether the sum was divided.
local function note_phase_scale(divided, device_count, phases_ok)
if scale_logged or not phases_ok then return end
if device_count == nil or device_count < 1 then return end
scale_logged = true
local divisor = 1
if divided then divisor = device_count end
host.log("info", string.format(
"SAJ eManager: phase voltage/frequency divisor %d", divisor))
end

----------------------------------------------------------------------------
-- Summary block → DER fields. Nil means the word did not decode.
----------------------------------------------------------------------------
Expand All @@ -445,7 +453,6 @@ end
local function decode_summary(regs)
local mode = regs[IDX_MODE]
if mode ~= nil and mode ~= 0xFFFF then
host.emit_metric("saj_emanager_mpv_mode", mode)
if mode == MODE_FAULT then
host.set_device_fault(true, "MPVMode 5 fault")
else
Expand All @@ -463,16 +470,6 @@ local function decode_summary(regs)
local user = u32_at(regs, IDX_USERCAP)
local soc_raw = regs[IDX_SOC]

-- No stated sign on these three. Keep the raw word off the DER streams.
local inv_w = i32_at(regs, IDX_INV)
if inv_w ~= nil then host.emit_metric("saj_emanager_inv_w_vendor", inv_w) end
local load_w = i32_at(regs, IDX_LOAD)
if load_w ~= nil then host.emit_metric("saj_emanager_load_w_vendor", load_w) end
local gen_w = i32_at(regs, IDX_GEN)
if gen_w ~= nil and gen_w ~= 0 then
host.emit_metric("saj_emanager_gen_w_vendor", gen_w)
end

local pv = {}
-- Generation is negative in every driver in this repository.
if pv_w ~= nil then pv.W = -pv_w end
Expand All @@ -487,12 +484,6 @@ local function decode_summary(regs)
if site_bat ~= nil then battery.W = site_bat end
local soc = soc_fraction(soc_raw)
if soc ~= nil then battery.SoC_nom_fract = soc end
if cap ~= nil then
host.emit_metric("saj_emanager_battery_capacity_raw", cap)
end
if user ~= nil then
host.emit_metric("saj_emanager_battery_available_raw", user)
end
end

return pv, meter, battery
Expand Down Expand Up @@ -534,11 +525,6 @@ local function apply_energy(pv, battery, regs)
if chg ~= nil then battery.total_charge_Wh = chg end
if dis ~= nil then battery.total_discharge_Wh = dis end
end
-- Vendor names, deliberately not import_wh / export_wh.
local feed = pair_wh(regs, PAIR_TOTAL_FEED_IN)
local sell = pair_wh(regs, PAIR_TOTAL_SELL)
if feed ~= nil then host.emit_metric("saj_emanager_vendor_feed_in_wh", feed) end
if sell ~= nil then host.emit_metric("saj_emanager_vendor_sell_wh", sell) end
end

local function emit_der(kind, fields)
Expand All @@ -550,7 +536,8 @@ end
----------------------------------------------------------------------------

function driver_init(config)
host.set_make("SAJ")
-- NovaCore brand key from /brands. "SAJ" is rejected.
host.set_make("saj")
host.set_model("eManager C1 Pro")
end

Expand All @@ -569,11 +556,7 @@ function driver_poll()
if phases then
divided = apply_phases(meter, phases, device_count)
end
if divided and device_count ~= nil then
host.emit_metric("saj_emanager_phase_scale_divisor", device_count)
elseif phases and device_count ~= nil and device_count >= 1 then
host.emit_metric("saj_emanager_phase_scale_divisor", 1)
end
note_phase_scale(divided, device_count, phases ~= nil)

local energy = probe_read(REG_ENERGY, ENERGY_WORDS, "holding")
if energy then
Expand Down Expand Up @@ -603,5 +586,6 @@ end

function driver_cleanup()
announced = false
scale_logged = false
read_failures = {}
end
49 changes: 15 additions & 34 deletions drivers/tests/test_saj-emanager.py
Original file line number Diff line number Diff line change
Expand Up @@ -197,11 +197,6 @@ def run_lua(body: str) -> dict[str, str]:
if obj == nil or obj[key] == nil then return "nil" end
return tostring(obj[key])
end
local function metric(name)
local m = host._metrics[name]
if m == nil or m.value == nil then return "nil" end
return tostring(m.value)
end
local pv = last(host._emitted["pv"])
local bat = last(host._emitted["battery"])
local met = last(host._emitted["meter"])
Expand Down Expand Up @@ -230,14 +225,7 @@ def run_lua(body: str) -> dict[str, str]:
print("SN " .. tostring(host._sn))
print("RATED " .. tostring(host._rated_w))
print("FAULT " .. tostring(host._faulted))
print("COUNT " .. metric("saj_emanager_device_count"))
print("DIVISOR " .. metric("saj_emanager_phase_scale_divisor"))
print("LOAD " .. metric("saj_emanager_load_w_vendor"))
print("INV " .. metric("saj_emanager_inv_w_vendor"))
print("GEN " .. metric("saj_emanager_gen_w_vendor"))
print("CAP " .. metric("saj_emanager_battery_capacity_raw"))
print("FEED " .. metric("saj_emanager_vendor_feed_in_wh"))
print("SELL " .. metric("saj_emanager_vendor_sell_wh"))
print("LOGS " .. table.concat(host._logs, " || "))
local slot_reads, slot_count, control_reads, bad_kind = 0, 0, 0, 0
for _, call in ipairs(host._calls) do
if call.func == "modbus_read" then
Expand Down Expand Up @@ -275,10 +263,10 @@ def test_three_inverter_plant_in_site_convention():
out = poll_once()

assert out["INTERVAL"] == "5000"
assert out["MAKE"] == "SAJ"
assert out["MAKE"] == "saj"
assert out["MODEL"] == "eManager C1 Pro"
assert out["SN"] == SERIALS[0]
assert out["COUNT"] == "3"
assert "DeviceNum=3" in out["LOGS"]
assert out["RATED"] == str(RATED_W)
assert out["FAULT"] == "false"
assert out["BAD_KIND"] == "0"
Expand All @@ -300,7 +288,6 @@ def test_three_inverter_plant_in_site_convention():
assert math.isclose(float(out["BAT_SOC"]), SOC_RAW / 10000, rel_tol=1e-6)
assert float(out["BAT_CHG"]) == BAT_CHARGE_RAW * 10
assert float(out["BAT_DIS"]) == BAT_DISCHARGE_RAW * 10
assert out["CAP"] == str(CAP_RAW)

# Wire -2500 is export on an import-positive register. Site export is −.
assert out["MET_EMITS"] == "1"
Expand All @@ -313,16 +300,11 @@ def test_three_inverter_plant_in_site_convention():
assert float(out["MET_L2W"]) == L2_W
assert float(out["MET_L3W"]) == L3_W
assert math.isclose(float(out["MET_L3V"]), (L1_V_RAW + 2) / 10, rel_tol=1e-6)
# Sheet scale was already one phase, so the divisor stays 1.
assert out["DIVISOR"] == "1"
# FeedIn / Sell stay vendor metrics. They are not import and export.
# Sheet scale was already one phase, so the logged divisor stays 1.
assert "divisor 1" in out["LOGS"]
# FeedIn / Sell are not import and export. Direction is unconfirmed.
assert out["MET_IMPORT"] == "nil"
assert out["MET_EXPORT"] == "nil"
assert float(out["FEED"]) == FEED_IN_RAW * 10
assert float(out["SELL"]) == SELL_RAW * 10
assert float(out["LOAD"]) == LOAD_W_VENDOR
assert float(out["INV"]) == INV_W_VENDOR
assert out["GEN"] == "nil"


def _i32_words(value: int) -> tuple[int, int]:
Expand Down Expand Up @@ -366,7 +348,7 @@ def test_summed_voltage_and_frequency_are_divided_power_is_not():
assert math.isclose(float(out["MET_L1V"]), L1_V_RAW / 10, rel_tol=1e-6)
assert math.isclose(float(out["MET_HZ"]), L1_HZ_RAW / 100, rel_tol=1e-6)
assert math.isclose(float(out["MET_L3V"]), (L1_V_RAW + 2) / 10, rel_tol=1e-6)
assert out["DIVISOR"] == "3"
assert "divisor 3" in out["LOGS"]
# Current and power are not part of that correction.
assert math.isclose(float(out["MET_L1A"]), L1_A_RAW / 10, rel_tol=1e-6)
assert float(out["MET_L1W"]) == L1_W
Expand All @@ -379,15 +361,15 @@ def test_implausible_voltage_that_does_not_divide_cleanly_is_left_alone():
out = poll_once(
f"host._modbus_registers.holding[{REG_PHASES}][1] = 4000")
assert math.isclose(float(out["MET_L1V"]), 400.0, rel_tol=1e-6)
assert out["DIVISOR"] == "1"
assert "divisor 1" in out["LOGS"]


def test_sum_is_not_guessed_when_device_count_did_not_answer():
out = poll_once(
f'host._modbus_read_fail_addresses[{REG_DEVICE_NUM}] = "timeout"\n'
f"host._modbus_registers.holding[{REG_PHASES}][3] = 15000")
assert out["COUNT"] == "nil"
assert out["DIVISOR"] == "nil"
assert "DeviceNum=" not in out["LOGS"]
assert "divisor" not in out["LOGS"]
assert out["SN"] == "nil"
assert out["SLOT_READS"] == "0"
# 150.00 Hz stays 150.00 Hz. Inventing a divisor of 3 would hide that.
Expand All @@ -398,7 +380,6 @@ def test_sum_is_not_guessed_when_device_count_did_not_answer():
def test_no_battery_when_capacity_soc_and_power_are_zero():
out = poll_once(pack="no")
assert out["BAT_EMITS"] == "0"
assert out["CAP"] == "nil"
assert out["PV_EMITS"] == "1"
assert out["MET_EMITS"] == "1"
assert float(out["PV_W"]) == -PV_W
Expand Down Expand Up @@ -459,7 +440,7 @@ def test_short_phase_block_does_not_zero_fill():
assert out["MET_L1V"] == "nil"
assert out["MET_L1W"] == "nil"
assert out["MET_HZ"] == "nil"
assert out["DIVISOR"] == "nil"
assert "divisor" not in out["LOGS"]


def test_phase_failure_keeps_the_totals():
Expand All @@ -478,8 +459,6 @@ def test_energy_failure_omits_counters():
assert float(out["BAT_W"]) == 6000
assert out["BAT_CHG"] == "nil"
assert out["BAT_DIS"] == "nil"
assert out["FEED"] == "nil"
assert out["SELL"] == "nil"


def test_int32_sentinel_is_not_a_power():
Expand All @@ -493,15 +472,15 @@ def test_int32_sentinel_is_not_a_power():

def test_zero_devices_does_not_scan_slots():
out = poll_once(count=0)
assert out["COUNT"] == "0"
assert "DeviceNum=0" in out["LOGS"]
assert out["SLOT_READS"] == "0"
assert out["SN"] == "nil"
assert out["PV_EMITS"] == "1"


def test_sentinel_device_count_does_not_scan_slots():
out = poll_once(count=0xFFFF)
assert out["COUNT"] == "nil"
assert "DeviceNum=" not in out["LOGS"]
assert out["SLOT_READS"] == "0"


Expand Down Expand Up @@ -569,6 +548,8 @@ def test_source_is_tcp_only_and_does_not_read_or_write_control():
code = _code_without_comments()
assert "RTU is not supported" in text
assert re.search(r"port\s*=\s*502", text)
assert 'set_make("saj")' in code
assert "host.emit_metric" not in code
# Mentioning the block in a string is the documentation. Reading or
# writing it is the bug.
assert not re.search(r"modbus_read\s*\([^)]*0x8400", code)
Expand Down
6 changes: 3 additions & 3 deletions index.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -536,14 +536,14 @@ drivers:
size_bytes: 10858
sha256: "38749fb157e0929c26c31ccb9e8013e3ee81f584349be1dd7cc60792b9e3adeb"
- name: "saj-emanager"
version: "0.1.1"
version: "0.1.2"
tier: community
protocol: modbus
connectivity: local
ders: [pv, battery, meter]
control: false
size_bytes: 25082
sha256: "4efc62ef56d5736e24895929d478a78788586796bb2d45be64acdd5051df640f"
size_bytes: 24245
sha256: "db7692001df4fcd19130c1a7e5b0f61f425f519bf2ba92be4ae1371c345da792"
- name: "saj"
version: "1.2.0"
tier: community
Expand Down
8 changes: 4 additions & 4 deletions manifests/saj-emanager.yaml
Original file line number Diff line number Diff line change
@@ -1,5 +1,5 @@
name: "saj-emanager"
version: "0.1.1"
version: "0.1.2"
tier: community
author: "Sourceful Labs AB"
protocol: modbus
Expand Down Expand Up @@ -28,11 +28,11 @@ upstream_docs:
kind: manual
url_stability: stable
min_host_version: "2.0.0"
size_bytes: 25082
size_bytes: 24245
dkb_id: ""
sha256: "4efc62ef56d5736e24895929d478a78788586796bb2d45be64acdd5051df640f"
sha256: "db7692001df4fcd19130c1a7e5b0f61f425f519bf2ba92be4ae1371c345da792"
signature: ""
bytecode_sha256: ""
bytecode_signature: ""
bytecode_size: 0
changelog: "Site signs match the catalog: PV negative, battery positive when charging, grid positive on import. Still read-only and untested on hardware."
changelog: "Brand key saj. Drop emit_metric; the NovaCore registry does not provide it. Still read-only and untested on hardware."
Loading