Skip to content

Packet reporting date and time to MCU causes exception #2

Description

@dreamlayers

Any one of these packets causes an exception:

55 AA 00 06 00 08 01 17 09 09 13 09 39 06 92
55 AA 00 06 00 08 01 17 09 09 13 0A 0B 06 65
55 AA 00 06 00 08 01 17 09 09 13 0C 36 06 92
55 AA 00 06 00 08 01 17 09 09 13 0D 2E 06 8B

They are logged from an Inkbird IBS-TH3-WIFI temperature and humidity sensor, sent from the BK7231N based CBU module to the HC32L110C6UA MCU. It contains date, time and day of the week. This is documented at https://developer.tuya.com/en/docs/iot/tuyacloudlowpoweruniversalserialaccessprotocol?id=K95afs9h4tjjh#title-13-Obtain%20the%20local%20time

This is from the backtrace:

System.ArgumentOutOfRangeException: Index was out of range. Must be non-negative and less than the size of the collection.
Parameter name: index
   at System.ThrowHelper.ThrowArgumentOutOfRangeException()
   at System.Collections.Generic.List`1.get_Item(Int32 index)
   at TuyaMCUAnalyzer.FormTuyaMCUAnalyzer.parseDPData(List`1 p, Int32 ofs)
   at TuyaMCUAnalyzer.FormTuyaMCUAnalyzer.displayPacket(List`1 p)
   at TuyaMCUAnalyzer.FormTuyaMCUAnalyzer.refresh()

It is possible to continue using the application after this, though the list of decoded packets gets truncated. As a workaround you can strip these packets out of the file.