Plant and numerical model

PowerControlLab models a standalone voltage-source inverter, not a grid-connected current-source converter. The topology is DC bus → ideal H-bridge → lossy L → shunt C → load. All internal quantities use SI units.

States and equations

Let i be the filter-inductor current, v the output voltage, u the bridge voltage, and i_load the load current. Kirchhoff's laws give

$$L\dot i=u-v-r_Li,\qquad C\dot v=i-i_{load}.$$

For a resistive load, i_load = v/R. With x = [i, v]ᵀ,

$$A=\begin{bmatrix}-r_L/L&-1/L\1/C&-1/(RC)\end{bmatrix},\quad B_u=\begin{bmatrix}1/L\0\end{bmatrix},\quad B_d=\begin{bmatrix}0\-1/C\end{bmatrix}.$$

The MPC model uses i_load = v/R_nom + d, with measured residual d held constant over each prediction horizon. It never receives the plant's actual L, C, future disturbance schedule, or rectifier capacitor state.

Default operating point

Quantity Value
DC source 400 V
Reference 230 Vrms, 50 Hz
L / C 2 mH / 20 µF
Inductor series resistance 0.15 Ω
Resistive load 50 Ω (about 1.06 kW at nominal voltage)
Controller and carrier frequency 20 kHz
Modulation limit ±0.98
Integration step 5 µs (10 substeps per control interval)
Simulation / soft start 240 ms / 20 ms

These are study parameters, not a reproduction of a commercial board. The unloaded LC resonance is approximately 796 Hz. The nominal reference peak is about 325 V, giving modulation headroom at 400 V. During the default 10% DC sag, the actuator limit is 352.8 V.

Dynamic nonlinear load

The nonlinear case adds a diode bridge, series resistance R_s, and a parallel DC capacitor/resistor to the existing AC resistor. Its third state is v_d, initially zero:

$$i_d=\max\left(\frac{|v|-v_d-2V_D}{R_s},0\right),\qquad C_d\dot v_d=i_d-\frac{v_d}{R_d},$$

$$i_{load}=\frac vR+\operatorname{sign}(v)i_d.$$

Defaults are R_s = 3 Ω, C_d = 470 µF, R_d = 100 Ω, and V_D = 0.7 V per diode. This produces capacitor charging pulses and an initial charging transient. It is a piecewise-smooth circuit model with finite source resistance; diode recovery and junction capacitance are omitted. The load remains passive. An independent test checks the complete instantaneous energy balance, including diode, source-resistor and DC-load dissipation.

Averaged and switched plants

In averaged mode, u = m V_dc during one control interval. This resolves the control and load dynamics but cannot reproduce carrier ripple, switching losses, or dead time.

In switching mode, the two bridge legs compare m and -m against the same triangular carrier c(φ) = 4|φ − 1/2| − 1, where 0 ≤ φ < 1. Thus

$$u=V_{dc}{\mathbf{1}[m\ge c]-\mathbf{1}[-m\ge c]}\in{-V_{dc},0,V_{dc}}.$$

The carrier runs at 20 kHz; unipolar bridge ripple also has components at twice that frequency. The integrator splits each fixed recording interval at exact PWM transition times. Duty ratio is not rounded to a small number of integration bins. Tests verify that the period-average bridge voltage equals m V_dc, including very short pulses.

Classical fourth-order Runge–Kutta advances the electrical states. Resistive-load trajectories are checked against an independent matrix exponential. A nonlinear load refinement test checks convergence when the integration step is halved. The script python scripts/validate_numerics.py records both averaged and switched convergence evidence.

The exported bridge_voltage is the mean voltage over the following recording bin; state samples are instantaneous at the bin boundaries. This distinction matters near switching transitions. The final command and bridge samples repeat the preceding values for plotting; metric windows exclude that final endpoint.

Causality and sensing

At each sample the controller reads noisy v, i, and i_load, plus the ideal measured DC bus. It computes a bridge-voltage request, which is limited to the common duty bound. Optional delay is a FIFO of modulation commands: a queued command uses the DC bus that exists when it is applied. Parameters and DC/load steps are constant within each control interval. Events must align with the controller clock.

All controllers share the same measurements. Noise draws are generated from the same seed and sample schedule. Metrics use true simulated states, not noise-corrupted observations.

Digital-twin scope

This release is a simulation-based digital-twin foundation. It has no live hardware connection, parameter-identification pipeline, sensor calibration, thermal model, magnetic saturation, switch loss model, dead time, grid synchronization, or hardware protection logic. The software tests verify its equations and numerical implementation; they do not validate a physical inverter. There is no claim of real-time execution, standards certification, global closed-loop stability, or controller superiority outside the reported experiments.

For physical topology context, see TI's single-phase inverter reference design. Its voltage-source mode also uses an LC output filter; our parameters and controller laws are independently chosen. Exact ZOH prediction uses SciPy's documented discretization interface.