24 changes: 12 additions & 12 deletions docs/doc-en.md
Original file line number Diff line number Diff line change
Expand Up @@ -91,17 +91,17 @@ Use impacts are not considered in our parametric model. They can nonetheless be

End-of-life impacts are the ratio of the card weight to the average impacts (by kilogram) of all cards analyzed during research. End-of-life impacts (by kilogram) are summarized in table 2.

| Name | Unit | PEF-AP (mol H+ eq.) | PEF-GWP (kg CO2 eq.) | PEF-CTUe (CTUe) | PEF-PM (Disease occurrence) | PEF-Epf (kg P eq.) | PEF-Epm (kg N eq.) | PEF-Ept (mol N eq.) | PEF-CTUh-c (CTUh) | PEF-CTUh-nc (CTUh) | PEF-IR (kBq U235 eq.) | PEF-LU (No dimension) | PEF-ODP (kg CFC-11 eq.) | PEF-POCP (kg NMVOC eq.) | PEF-ADPf (MJ) | PEF-ADPe (kg SB eq.) | PEF-WU (m3 eq.) |
|------------------------------|---------------------------|----------------------------|-----------------------------|------------------------|------------------------------------|---------------------------|---------------------------|----------------------------|--------------------------|---------------------------|------------------------------|------------------------------|--------------------------------|--------------------------------|----------------------|-----------------------------|------------------------|
| Casing | 1 kilogram | 5,96E-02 | 8,25E+00 | 4,09E+02 | 3,74E-07 | 3,90E-05 | 6,62E-03 | 7,24E-02 | 3,47E-08 | 3,22E-06 | 4,78E+00 | 5,07E-01 | 1,26E-06 | 2,51E-02 | 2,43E+02 | 4,08E-04 | 3,89E+00 |
| Heatsink | 1 kilogram | 2,18E-01 | 5,74E+00 | 4,20E+02 | 1,36E-06 | 1,50E-03 | 5,22E-03 | 6,04E-02 | 2,15E-05 | 2,78E-06 | 3,25E+02 | 3,54E+00 | 1,15E-06 | 2,99E-02 | 8,50E+01 | 1,87E-03 | 1,05E+01 |
| PCB | 1 square centimeter | 3,16E-04 | 3,25E-02 | 5,24E-01 | 1,70E-09 | 1,21E-07 | 2,45E-05 | 2,64E-04 | 4,22E-09 | 1,69E-09 | 9,69E-02 | 1,39E-04 | 4,80E-09 | 9,71E-05 | 5,10E-01 | 1,27E-05 | 1,62E-02 |
| GPU | 1 square millimeter | 2,35E-04 | 4,26E-02 | 5,44E-01 | 1,30E-09 | 1,33E-07 | 2,83E-05 | 2,94E-04 | 9,72E-12 | 2,32E-10 | 4,60E-04 | 1,70E-04 | 1,86E-08 | 9,25E-05 | 5,56E-01 | 1,55E-08 | 1,48E-02 |
| VRAM | 1 square millimeter | 1,01E-03 | 1,84E-01 | 2,35E+00 | 5,59E-09 | 5,72E-07 | 1,22E-04 | 1,27E-03 | 1,72E-11 | 9,95E-10 | 1,54E-03 | 7,31E-04 | 8,01E-08 | 3,99E-04 | 2,40E+00 | 5,07E-09 | 7,08E-02 |
| Upstream transport | 1 kilogram | 1,73E-03 | 2,60E-01 | 1,75E-01 | 1,50E-08 | 9,71E-08 | 8,16E-04 | 8,96E-03 | 4,63E-12 | 5,73E-10 | 6,31E-04 | 0,00E+00 | 3,97E-10 | 2,27E-03 | 3,61E+00 | 1,02E-08 | 9,84E-04 |
| Transport - truck | 1 kg.km | 3,19E-07 | 5,04E-05 | 3,39E-05 | 2,59E-12 | 1,89E-11 | 1,50E-07 | 1,64E-06 | 8,85E-16 | 9,58E-14 | 1,23E-07 | 0,00E+00 | 7,72E-14 | 4,14E-07 | 7,03E-04 | 1,98E-12 | 1,91E-07 |
| Transport - boat | 1 kg.km | 5,34E-07 | 1,33E-05 | 7,92E-06 | 2,76E-12 | 4,46E-12 | 1,22E-07 | 1,34E-06 | 1,89E-16 | 4,28E-14 | 2,63E-08 | 0,00E+00 | 1,65E-14 | 3,45E-07 | 1,63E-04 | 4,62E-13 | 4,20E-08 |
| Transport - plane | 1 kg.km | 8,77E-06 | 2,11E-03 | 1,37E-03 | 5,44E-11 | 7,44E-10 | 3,95E-06 | 4,32E-05 | 3,19E-14 | 1,67E-12 | 3,89E-06 | 0,00E+00 | 2,44E-12 | 1,06E-05 | 2,95E-02 | 8,31E-11 | 8,38E-06 |
| End-of-life | 1 kilogram | 3,17E-02 | 1,51E+00 | 7,62E+02 | 9,63E-08 | 3,11E-05 | 2,11E-02 | 1,47E-02 | 5,89E-09 | 2,33E-07 | 1,23E-01 | 6,74E+00 | 1,39E-07 | 5,37E-03 | 1,95E+01 | 3,71E-06 | 7,30E+02 |
| Name | Unit | PEF-AP (mol H+ eq.) | PEF-GWP (kg CO2 eq.) | PEF-CTUe (CTUe) | PEF-PM (Disease occurrence) | PEF-Epf (kg P eq.) | PEF-Epm (kg N eq.) | PEF-Ept (mol N eq.) | PEF-CTUh-c (CTUh) | PEF-CTUh-nc (CTUh) | PEF-IR (kBq U235 eq.) | PEF-LU (No dimension) | PEF-ODP (kg CFC-11 eq.) | PEF-POCP (kg NMVOC eq.) | PEF-ADPf (MJ) | PEF-ADPe (kg SB eq.) | PEF-WU (m3 eq.) |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Casing | 1 kilogram | 7,28E-02 | 7,82E+00 | 4,04E+02 | 4,57E-07 | 1,72E-04 | 6,95E-02 | 6,32E-03 | 2,00E-06 | 3,03E-06 | 3,41E+01 | 7,62E-01 | 1,21E-06 | 2,49E-02 | 2,20E+02 | 4,96E-04 | 4,32E+00 |
| Heatsink | 1 kilogram | 2,18E-01 | 5,74E+00 | 4,20E+02 | 1,36E-06 | 1,50E-03 | 6,04E-02 | 5,22E-03 | 2,15E-05 | 2,78E-06 | 3,25E+02 | 3,54E+00 | 1,15E-06 | 2,99E-02 | 8,50E+01 | 1,87E-03 | 1,05E+01 |
| PCB | 1 square centimeter | 5,76E-04 | 7,30E-02 | 1,03E+00 | 3,12E-09 | 2,38E-07 | 5,51E-04 | 5,17E-05 | 4,83E-09 | 2,91E-09 | 1,06E-01 | 2,55E-04 | 1,62E-08 | 1,91E-04 | 9,99E-01 | 2,13E-05 | 3,15E-02 |
| GPU | 1 square millimeter | 2,40E-04 | 4,32E-02 | 5,52E-01 | 1,32E-09 | 1,35E-07 | 2,99E-04 | 2,87E-05 | 1,63E-10 | 2,65E-10 | 2,67E-03 | 1,72E-04 | 1,89E-08 | 9,40E-05 | 5,65E-01 | 1,94E-07 | 1,50E-02 |
| VRAM | 1 square millimeter | 1,90E-04 | 3,45E-02 | 4,40E-01 | 1,05E-09 | 1,07E-07 | 2,38E-04 | 2,29E-05 | 3,23E-12 | 1,87E-10 | 2,89E-04 | 1,37E-04 | 1,50E-08 | 7,48E-05 | 4,50E-01 | 9,51E-10 | 1,33E-02 |
| Upstream transport | 1 kilogram | 1,74E-03 | 2,61E-01 | 1,76E-01 | 1,50E-08 | 9,78E-08 | 9,01E-03 | 8,22E-04 | 4,66E-12 | 5,77E-10 | 6,35E-04 | 0,00E+00 | 4,00E-10 | 2,28E-03 | 3,64E+00 | 1,03E-08 | 9,90E-04 |
| Transport - truck | 1 kg.km | 3,19E-07 | 5,04E-05 | 3,39E-05 | 2,59E-12 | 1,89E-11 | 1,50E-07 | 1,64E-06 | 8,85E-16 | 9,58E-14 | 1,23E-07 | 0,00E+00 | 7,72E-14 | 4,14E-07 | 7,03E-04 | 1,98E-12 | 1,91E-07 |
| Transport - boat | 1 kg.km | 5,34E-07 | 1,33E-05 | 7,92E-06 | 2,76E-12 | 4,46E-12 | 1,22E-07 | 1,34E-06 | 1,89E-16 | 4,28E-14 | 2,63E-08 | 0,00E+00 | 1,65E-14 | 3,45E-07 | 1,63E-04 | 4,62E-13 | 4,20E-08 |
| Transport - plane | 1 kg.km | 8,77E-06 | 2,11E-03 | 1,37E-03 | 5,44E-11 | 7,44E-10 | 3,95E-06 | 4,32E-05 | 3,19E-14 | 1,67E-12 | 3,89E-06 | 0,00E+00 | 2,44E-12 | 1,06E-05 | 2,95E-02 | 8,31E-11 | 8,38E-06 |
| End-of-life | 1 kilogram | 3,16E-02 | 1,48E+00 | 7,62E+02 | 9,40E-08 | 3,01E-05 | 2,11E-02 | 1,44E-02 | 5,58E-09 | 2,32E-07 | 1,20E-01 | 6,61E+00 | 1,36E-07 | 5,29E-03 | 1,90E+01 | 3,43E-06 | 7,02E+02 |

**Table 2:** Average impact factors by component
24 changes: 12 additions & 12 deletions docs/doc-fr.md
Original file line number Diff line number Diff line change
Expand Up @@ -91,17 +91,17 @@ Les impacts à l’usage ne sont pas pris en compte dans le modèle paramétriqu
Les impacts de la fin de vie de la carte sont modélisés à travers un ratio poids basés sur les impacts moyen de la fin de vie par kilogramme de carte pour les 7 cartes analysées. Les impacts de la fin de vie par kg de carte sont reportés dans le Tableau 2.


| Name | Unité | PEF-AP (mol H+ eq.) | PEF-GWP (kg CO2 eq.) | PEF-CTUe (CTUe) | PEF-PM (Disease occurrence) | PEF-Epf (kg P eq.) | PEF-Epm (kg N eq.) | PEF-Ept (mol N eq.) | PEF-CTUh-c (CTUh) | PEF-CTUh-nc (CTUh) | PEF-IR (kBq U235 eq.) | PEF-LU (No dimension) | PEF-ODP (kg CFC-11 eq.) | PEF-POCP (kg NMVOC eq.) | PEF-ADPf (MJ) | PEF-ADPe (kg SB eq.) | PEF-WU (m3 eq.) |
|------------------------------|---------------------------|----------------------------|-----------------------------|------------------------|------------------------------------|---------------------------|---------------------------|----------------------------|--------------------------|---------------------------|------------------------------|------------------------------|--------------------------------|--------------------------------|----------------------|-----------------------------|------------------------|
| Boîtier | 1kg de Boîtier | 5,96E-02 | 8,25E+00 | 4,09E+02 | 3,74E-07 | 3,90E-05 | 6,62E-03 | 7,24E-02 | 3,47E-08 | 3,22E-06 | 4,78E+00 | 5,07E-01 | 1,26E-06 | 2,51E-02 | 2,43E+02 | 4,08E-04 | 3,89E+00 |
| Radiateur | 1kg de radiateur | 2,18E-01 | 5,74E+00 | 4,20E+02 | 1,36E-06 | 1,50E-03 | 5,22E-03 | 6,04E-02 | 2,15E-05 | 2,78E-06 | 3,25E+02 | 3,54E+00 | 1,15E-06 | 2,99E-02 | 8,50E+01 | 1,87E-03 | 1,05E+01 |
| PCB | 1 cm2 de PCB | 3,16E-04 | 3,25E-02 | 5,24E-01 | 1,70E-09 | 1,21E-07 | 2,45E-05 | 2,64E-04 | 4,22E-09 | 1,69E-09 | 9,69E-02 | 1,39E-04 | 4,80E-09 | 9,71E-05 | 5,10E-01 | 1,27E-05 | 1,62E-02 |
| GPU | 1 mm2 de puce GPU | 2,35E-04 | 4,26E-02 | 5,44E-01 | 1,30E-09 | 1,33E-07 | 2,83E-05 | 2,94E-04 | 9,72E-12 | 2,32E-10 | 4,60E-04 | 1,70E-04 | 1,86E-08 | 9,25E-05 | 5,56E-01 | 1,55E-08 | 1,48E-02 |
| VRAM | 1 mm2 de puce VRAL | 1,01E-03 | 1,84E-01 | 2,35E+00 | 5,59E-09 | 5,72E-07 | 1,22E-04 | 1,27E-03 | 1,72E-11 | 9,95E-10 | 1,54E-03 | 7,31E-04 | 8,01E-08 | 3,99E-04 | 2,40E+00 | 5,07E-09 | 7,08E-02 |
| Transport amont | 1kg de carte | 1,73E-03 | 2,60E-01 | 1,75E-01 | 1,50E-08 | 9,71E-08 | 8,16E-04 | 8,96E-03 | 4,63E-12 | 5,73E-10 | 6,31E-04 | 0,00E+00 | 3,97E-10 | 2,27E-03 | 3,61E+00 | 1,02E-08 | 9,84E-04 |
| Transport - camion | 1 kg.km | 3,19E-07 | 5,04E-05 | 3,39E-05 | 2,59E-12 | 1,89E-11 | 1,50E-07 | 1,64E-06 | 8,85E-16 | 9,58E-14 | 1,23E-07 | 0,00E+00 | 7,72E-14 | 4,14E-07 | 7,03E-04 | 1,98E-12 | 1,91E-07 |
| Transport - bateau | 1 kg.km | 5,34E-07 | 1,33E-05 | 7,92E-06 | 2,76E-12 | 4,46E-12 | 1,22E-07 | 1,34E-06 | 1,89E-16 | 4,28E-14 | 2,63E-08 | 0,00E+00 | 1,65E-14 | 3,45E-07 | 1,63E-04 | 4,62E-13 | 4,20E-08 |
| Transport - avion | 1 kg.km | 8,77E-06 | 2,11E-03 | 1,37E-03 | 5,44E-11 | 7,44E-10 | 3,95E-06 | 4,32E-05 | 3,19E-14 | 1,67E-12 | 3,89E-06 | 0,00E+00 | 2,44E-12 | 1,06E-05 | 2,95E-02 | 8,31E-11 | 8,38E-06 |
| Fin de vie | 1kg de carte | 3,17E-02 | 1,51E+00 | 7,62E+02 | 9,63E-08 | 3,11E-05 | 2,11E-02 | 1,47E-02 | 5,89E-09 | 2,33E-07 | 1,23E-01 | 6,74E+00 | 1,39E-07 | 5,37E-03 | 1,95E+01 | 3,71E-06 | 7,30E+02 |
| Name | Unité | PEF-AP (mol H+ eq.) | PEF-GWP (kg CO2 eq.) | PEF-CTUe (CTUe) | PEF-PM (Disease occurrence) | PEF-Epf (kg P eq.) | PEF-Epm (kg N eq.) | PEF-Ept (mol N eq.) | PEF-CTUh-c (CTUh) | PEF-CTUh-nc (CTUh) | PEF-IR (kBq U235 eq.) | PEF-LU (No dimension) | PEF-ODP (kg CFC-11 eq.) | PEF-POCP (kg NMVOC eq.) | PEF-ADPf (MJ) | PEF-ADPe (kg SB eq.) | PEF-WU (m3 eq.) |
| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |
| Boîtier | 1kg de Boîtier | 7,28E-02 | 7,82E+00 | 4,04E+02 | 4,57E-07 | 1,72E-04 | 6,95E-02 | 6,32E-03 | 2,00E-06 | 3,03E-06 | 3,41E+01 | 7,62E-01 | 1,21E-06 | 2,49E-02 | 2,20E+02 | 4,96E-04 | 4,32E+00 |
| Radiateur | 1kg de radiateur | 2,18E-01 | 5,74E+00 | 4,20E+02 | 1,36E-06 | 1,50E-03 | 6,04E-02 | 5,22E-03 | 2,15E-05 | 2,78E-06 | 3,25E+02 | 3,54E+00 | 1,15E-06 | 2,99E-02 | 8,50E+01 | 1,87E-03 | 1,05E+01 |
| PCB | 1 cm2 de PCB | 5,76E-04 | 7,30E-02 | 1,03E+00 | 3,12E-09 | 2,38E-07 | 5,51E-04 | 5,17E-05 | 4,83E-09 | 2,91E-09 | 1,06E-01 | 2,55E-04 | 1,62E-08 | 1,91E-04 | 9,99E-01 | 2,13E-05 | 3,15E-02 |
| GPU | 1 mm2 de puce GPU | 2,40E-04 | 4,32E-02 | 5,52E-01 | 1,32E-09 | 1,35E-07 | 2,99E-04 | 2,87E-05 | 1,63E-10 | 2,65E-10 | 2,67E-03 | 1,72E-04 | 1,89E-08 | 9,40E-05 | 5,65E-01 | 1,94E-07 | 1,50E-02 |
| VRAM | 1 mm2 de puce VRAL | 1,90E-04 | 3,45E-02 | 4,40E-01 | 1,05E-09 | 1,07E-07 | 2,38E-04 | 2,29E-05 | 3,23E-12 | 1,87E-10 | 2,89E-04 | 1,37E-04 | 1,50E-08 | 7,48E-05 | 4,50E-01 | 9,51E-10 | 1,33E-02 |
| Transport amont | 1kg de carte | 1,74E-03 | 2,61E-01 | 1,76E-01 | 1,50E-08 | 9,78E-08 | 9,01E-03 | 8,22E-04 | 4,66E-12 | 5,77E-10 | 6,35E-04 | 0,00E+00 | 4,00E-10 | 2,28E-03 | 3,64E+00 | 1,03E-08 | 9,90E-04 |
| Transport - camion | 1 kg.km | 3,19E-07 | 5,04E-05 | 3,39E-05 | 2,59E-12 | 1,89E-11 | 1,50E-07 | 1,64E-06 | 8,85E-16 | 9,58E-14 | 1,23E-07 | 0,00E+00 | 7,72E-14 | 4,14E-07 | 7,03E-04 | 1,98E-12 | 1,91E-07 |
| Transport - bateau | 1 kg.km | 5,34E-07 | 1,33E-05 | 7,92E-06 | 2,76E-12 | 4,46E-12 | 1,22E-07 | 1,34E-06 | 1,89E-16 | 4,28E-14 | 2,63E-08 | 0,00E+00 | 1,65E-14 | 3,45E-07 | 1,63E-04 | 4,62E-13 | 4,20E-08 |
| Transport - avion | 1 kg.km | 8,77E-06 | 2,11E-03 | 1,37E-03 | 5,44E-11 | 7,44E-10 | 3,95E-06 | 4,32E-05 | 3,19E-14 | 1,67E-12 | 3,89E-06 | 0,00E+00 | 2,44E-12 | 1,06E-05 | 2,95E-02 | 8,31E-11 | 8,38E-06 |
| Fin de vie | 1kg de carte | 3,16E-02 | 1,48E+00 | 7,62E+02 | 9,40E-08 | 3,01E-05 | 2,11E-02 | 1,44E-02 | 5,58E-09 | 2,32E-07 | 1,20E-01 | 6,61E+00 | 1,36E-07 | 5,29E-03 | 1,90E+01 | 3,43E-06 | 7,02E+02 |

Tableau 1 - Facteurs d'impact par composant