Integrate APsystems EZ1 Inverter into Victron Energies Venus OS
With the scripts in this repo it should be easy possible to install, uninstall, restart a service that connects the APsystems EZ1 Inverter to the VenusOS and GX devices from Victron. This repo is based on the great work of @vikt0rm and others.
This repository is a modification of https://github.com/vikt0rm/dbus-shelly-1pm-pvinverter.
As mentioned above the script is inspired by @fabian-lauer dbus-shelly-3em-smartmeter implementation. So what is the script doing:
- Running as a service
- connecting to DBus of the Venus OS
com.victronenergy.pvinverter.http_{DeviceInstanceID_from_config} - After successful DBus connection APsystems EZ1 Inverter is called via api and values are being published on DBus
- The device system time gets updated to allow daly production reset
- Serial is taken from the config file, auto detection is possible but not implemented
- Paths are added to the DBus with default value 0 - including some settings like name, etc
- After that a "loop" is started which pulls APsystems EZ1 Inverter data every x seconds
- The interval can be configured through the config file
Just grap a copy of the main branche and copy them to a folder under /data/ e.g. /data/dbus-apsystems-ez1.
After that call the install.sh script.
The following script should do everything for you:
wget https://github.com/domizei385/dbus-apsystems-ez1/archive/refs/heads/main.zip
unzip main.zip && mv dbus-apsystems-ez1-main /data/dbus-apsystems-ez1 && rm main.zip
cd /data/dbus-apsystems-ez1/
chmod a+x install.sh
./install.sh
Within the project there is a file /data/dbus-apsystems-ez1/config.ini - just change the values - most important is the deviceinstance, custom name and phase under "DEFAULT" and host, username and password in section "ONPREMISE". More details below:
| Section | Config vlaue | Explanation |
|---|---|---|
| DEFAULT | Address | IP or hostname of APsystems EZ1 Inverter |
| DEFAULT | Port | The port on which APsystems EZ1 Inverter API is running |
| DEFAULT | Serial | The serial number of the logger integrated in the inverter |
| DEFAULT | Phase | Valid values L1, L2 or L3: represents the phase where pv inverter is feeding in |
| DEFAULT | SignOfLifeLog | Time in minutes how often a status is added to the log-file current.log with log-level INFO |
| DEFAULT | Deviceinstance | Unique ID identifying the APsystems EZ1 Inverter in Venus OS |
| DEFAULT | CustomName | Name shown in Remote Console (e.g. name of pv inverter) |
| DEFAULT | Position | Valid values 0, 1 or 2: represents where the inverter is connected (0=AC input 1; 1=AC output; 2=AC input 2) |
| DEFAULT | UpdateInterval | The interval how often the data is read from the inverter in seconds. The inverter itself accumulates the values every 5 minutes. |
If you encounter any issue please test your settings in config.ini with:
cd /data/dbus-apsystems-ez1/
chmod a+x test-config.py
./test-config.py
There should be no error message but some JSON like output with data fetched from your inverter.
- https://github.com/victronenergy/venus/wiki/dbus#pv-inverters DBus paths for Victron namespace
- https://github.com/victronenergy/venus/wiki/dbus-api DBus API from Victron
- https://www.victronenergy.com/live/ccgx:root_access How to get root access on GX device/Venus OS