Skip to content

Cut idle CPU on battery about 8x without dropping features - #3

Merged
arshdwani merged 1 commit into
mainfrom
battery-idle-cost
Oct 28, 2026
Merged

arshdwani merged 1 commit into
mainfrom
battery-idle-cost

Conversation

@arshdwani

Copy link
Copy Markdown
Owner

What

With the panel closed on battery (the all-day case), Dynamo used ~51 ms of CPU per minute in 1.6; it now uses ~6. No features removed.

Panel closed, on battery 1.6 This PR
Daemon (side by side, 295 s, proc_pid_rusage) 33.3 ms/min 2.95 ms/min
App (5 min each) 18 ms/min 3.1 ms/min
  • Essentials-only battery read (BatteryInfo.read(essentialsOnly:)): 9 keys instead of the whole AppleSmartBattery entry, 0.25 vs 1.6 ms on a cold wakeup. Used by the daemon and by the app while its panel is closed; the open panel still reads everything.
  • Daemon checks every 30 s on battery, every 5 s on power as before. Power source notifications (only a change in ExternalConnected) and a watch on config.json trigger a check at once, so settings now apply in ~0.3 s instead of up to 5 s.
  • Config is parsed again only when its mtime or size changed (0.2 → 0.01 ms).
  • Status heartbeat touches the file instead of rewriting it when nothing changed (1.6 ms → a utimes); DaemonStatus.load counts the file's date as updatedAt.
  • App polls every 60 s instead of 20 s while closed; battery notifications still update the icon at once.

Checked

  • ./build.sh test: all pass, including a new check that the essentials-only read matches the full read (skipped without a battery, as on CI).
  • Old and new daemons run side by side as a user against private data dirs: new reacted to a config change in ~0.3 s (old: next 5 s tick), consumed the request and cleared it; heartbeat every 30–36 s; the CLI still reports the service running when the JSON's updatedAt is 91 s old but the file was touched 25 s ago.
  • Not verified: the immediate check on plugging in (no charger access); the 30 s check covers it, and charging state is already right before plugging in.

Measured over 5 minutes on battery with the panel closed: the daemon went
from 33.3 to 2.95 ms of CPU per minute, the app from 18 to 3.1.

- Battery reads take only the 9 keys the daemon and menu bar icon use,
  instead of copying the whole AppleSmartBattery entry (0.25 vs 1.6 ms when
  cold). The open panel still reads everything.
- The daemon checks every 30 s on battery, where nothing charges, and every
  5 s on power as before. Plugging in or unplugging (power source
  notifications) and config changes (a file watch) trigger a check at once,
  so settings now apply in ~0.3 s instead of up to 5 s.
- Config is parsed again only when the file's mtime or size changed.
- An unchanged status is refreshed by touching the file instead of rewriting
  it (1.6 ms); DaemonStatus.load counts the file's date as updatedAt.
- The app polls every 60 s instead of 20 s while the panel is closed.
@arshdwani
arshdwani merged commit 022aa40 into main Oct 28, 2026
2 checks passed
@arshdwani
arshdwani deleted the battery-idle-cost branch October 28, 2026 14:48