Skip to content

ahmhabib01/Humidity-automation

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

33 Commits
 
 
 
 
 
 
 
 

Repository files navigation


cell1 cell2

🚀 Humidity Automation 💧

🎯 Project Goal

To build an extremely reliable, Wi-Fi-controlled, and aesthetically pleasing Automated Humidifier Controller using the ESP8266, eliminating the common problems of relay chattering and sensor failure through smart safety logic.


Edge

Feature Impact Status
🌐 Offline Dominance Full dashboard control without any active internet connection (zero dependency on Google APIs). DONE
🛡️ Fail-Safe Logic Critical sensor errors automatically force the humidifier OFF, preventing accidental flooding or burnout. DONE
🧠 Intelligent Stability Uses Hysteresis to stabilize switching behavior, maximizing relay life. DONE
🎨 Hyper-Responsive UI Fast, dark-mode, mobile-friendly dashboard served instantly from the ESP8266's memory. DONE

⚙️ Core Technology

cell1 cell2 cell3 cell4
Component Role Pins Used (NodeMCU)
Microcontroller ESP8266 Wi-Fi Station/AP Mode, Web Server
Sensor DHT22 D2 (GPIO4): Humidity & Temp Data
Actuator 1-Channel Relay D1 (GPIO5): Humidifier Control (Active-LOW)
Output Device Humidifier Generates mist (Ultrasonic/USB Mist Maker)

🌐 Connectivity

The device attempts to connect to your home Wi-Fi first (STA Mode). If credentials are not set or connection fails, it falls back to a self-created Access Point (AP).

Mode Network Name Access IP Access Requirement
STA Mode (Home Wi-Fi) Your Router's SSID 192.168.x.xxx Device must be on the same network.
AP Mode (Direct Link) BDC_2.0 (Pass: ahmhabib01) 192.168.4.1 No Internet Required. Connect directly to this network.

🛠️ Setup Guide

1. 🔌 Hardware Wiring

Carefully connect the components as detailed below:

Component Pin ESP8266 Pin (GPIO) Notes
DHT22 VCC 3.3V Power for the sensor.
DHT22 GND GND Ground connection.
DHT22 Data D2 (GPIO4) Sensor Data Input.
Relay VCC VIN (5V) / VCC Relay Coil Power Supply.
Relay GND GND Relay Ground.
Relay IN D1 (GPIO5) Control Signal from ESP. (Active-LOW Logic)

|Humidifier Power (+) | Connect to Relay NO (Normally Open) terminal|

|Power Source (+) | Connect to Relay COM (Common) terminal|

|Humidifier Ground (-) | Connect directly to Power Source Ground (-)|

⚠️ Safety Note: Connect the humidifier's power line to the relay's Common (COM) and Normally Open (NO) terminals. Never connect high voltage while the ESP8266 is powered on.


2. 💻 Software and Library Installation


  1. Open Arduino IDE and go to File > Preferences.
  2. Add the following URL to "Additional Boards Manager URLs":
    http://arduino.esp8266.com/stable/package_esp8266com_index.json
    
  3. Go to Tools > Board > Boards Manager... and search for esp8266. Install the latest package.
  4. Go to Sketch > Include Library > Manage Libraries... and install the following:
    • DHT sensor library by Adafruit
    • Adafruit Unified Sensor

3. ⚙️ Code Configuration and Upload

  1. Download and open humidity.ino with Arduino IDE
  2. Optional: Update the Wi-Fi credentials for STA Mode (if using your home network):
    const char* ssid = "YOUR_HOME_WIFI_NAME";
    const char* password = "YOUR_WIFI_PASSWORD";
  3. Select the correct board (e.g., NodeMCU 1.0) and Port under Tools.
  4. Click the Upload button (Right Arrow icon).
  5. Wait for the Done uploading. message.

🖥️ Accessing the Dashboard

  1. Open the Serial Monitor (115200 Baud) and wait for the "IP Address" to be printed.
  2. Open a web browser (on a device connected to the relevant Wi-Fi network) and enter the IP address.
Mode Network Name Access IP Access Requirement
STA Mode (Home Wi-Fi) Your Router's SSID 192.168.x.xxx (Dynamic IP) Device must be on the same home network.
AP Mode (Direct Link) BDC_2.0 (Pass: ahmhabib01) 192.168.4.1 (Static IP) Connect directly to the BDC_2.0 network.

💡 Tip: If the dashboard doesn't load in AP Mode, ensure your phone's Mobile Data is temporarily turned OFF.


🧠 Core Logic: The Hysteresis Principle

Humidity Automation uses a $5%$ hysteresis band to maintain target humidity and prevent short-cycling.

  • Target (e.g., 65%): The ideal max humidity.
  • Humidifier ON: Only when Humidity $\le$ $60%$ ($\text{Target} - 5%$).
  • Humidifier OFF: Only when Humidity $\ge$ $65%$ ($\text{Target}$).