4 changes: 4 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -28,6 +28,10 @@ All notable changes to `OWNd` are documented in this file.
- **WHO 4 (`OWNHeatingEvent`)**: `OWNMessage.parse` / `OWNEvent.parse` no longer raise on a WHO 4 frame the grammar accepts but the decoder could not read: an empty DIMENSION 11 / 13 / 60 value (`*#4*1*11*##`, `*#4*1*60*##` raised `ValueError`; `*#4*1*11##`, `*#4*1*13##`, `*#4*1*60##` raised `IndexError`), an empty DIMENSION 15 sensor slot (`*#4*1*15**##`, `*#4*1*15**0215##`, `*#4*1*15#1**0215##` raised `ValueError` from `int('')`) and the wildcard WHERE (`*4*1**##`, `*4*303**##` raised `ValueError` from `int('*')`; the event is zone 0, as a frame without a WHERE already was). Such a frame stays untyped with `fan_speed` / `fan_on` / `main_humidity` / `secondary_temperature` `None`. The integer fields of DIMENSION 11, 15, 19, 20, 30, 31 and 32 are read only when they are ASCII digits, as the DIMENSION 60 humidity value already was (`str.isdigit` also accepts fullwidth digits: `*#4*1*11*3*##` decoded `fan_speed` 3, `*#4*#0*30*01*02*2026##` a date; both are untyped now). Crash guards only: every well-formed ASCII frame decodes exactly as before (same `message_type`, property values and log lines).
- **WHO 18 (send layer, `is_who18_dimension_52_crash_form`)**: a DIMENSION 52 request that is not one of the tested safe forms is refused by every send path (`OWNCommandSession.send`, `send_to_gateway`, `AsyncTcpTransport.send`, `AsyncSerialTransport.send`) with `reason="destructive_frame"`, like the WHO 4 dimension 22 crash forms: `*#18*51*52#2026#10##` and `*#18*51*52#2026#10*100##` crash the F460 `020012`, F461 `020011` and 3488 `030205` (HOMETOUCH) after the telegram went out (OpenWebNet-HA/own-firmware-oracle, suite `ownd-audit-frames`, index SHA-256 `db03cc878d84d514b9e324c2d01d050264f2e4ccd0c1aad33937683c30e472ca`, `findings/audit-crash-frames.md`; emulated firmware, `harness=full`, not yet replayed on physical hardware). The firmware reads the year with `atoi()` into one byte, so every spelling it reads as a wide year is refused too (`52#02026#10`, `52#256#10`, `*#018*`, `*052`, `#010`, a `#52` write, an extra `#` parameter, an empty WHERE, a non-ASCII digit, more than one value field); only `*#18*WHERE*52##`, `*#18*WHERE*52*Wh##`, `*#18*WHERE*52#YY#M##` and `*#18*WHERE*52#YY#M*Wh##` with a one- or two-digit year and a month 1..12 go out. `bytes` / `bytearray` / `memoryview` and concatenated `##` chunks are checked like the WHO 4 guard. No builder emits a refused form and `OWNCommand.parse` stays permissive. `is_who18_dimension_52_four_digit_year` remains as an alias.

### Added
- **WHO 4 (`OWNHeatingEvent.actuator`, `OWNHeatingCommand.actuator`, `OWNMessage.interface`)**: Public `actuator` property on Dimension 20 status events (`*#4*Z#N*20*VAL##`), Dimension 20 requests (`*#4*Z#N*20##`) and `MyHomeServer1` Dimension 20 writes (`*#4*Z#N*#20*VAL##`), plus WHO 4 `#4#IF` bus-interface extraction in `OWNMessage.interface` and `OWNMessage.event_content` (`MyHOME#863`). Disambiguates actuator `#4` (`30#4`, `len == 1`) from F422 bus routing (`30#4#01`, `len == 2`, actuator `"1"`; `30#4#4#01`, `len == 3`, actuator `"4"` on interface `"01"`), `#0#4` (4-zone central unit 4) from `#0#4#01` (`#0` on interface `"01"`), and leaves WHO 4 Dimension 22 split addresses (`3#4#1*22##`) unrouted.
- **Profiles (`GatewayProfile` WHO 4 request capability flags)**: Declarative `bool | None = None` fields `supports_general_heating_status` (`*#4*0##`), `supports_heating_zone_status` (`*#4*Z##`), `supports_heating_actuator_status` (`*#4*Z*20##`), `supports_heating_humidity_request` (`*#4*Z*60##`), and `supports_interface_zone_requests` (`*#4*Z#4#II...##`) populated from `own-firmware-oracle` verdicts and live hardware traces (`MyHOME#466`, `#629`, `#674`, `#799`, `#866`), with `F454Profile(supports_heating_zone_status=True, ...)` and `MH202Profile(supports_heating_zone_status=True, ...)` verified on both central-unit (`#629`) and standalone room-thermostat (`#866`) plants.

## [2.0.0b13] - 2026-11-02

### Added
Expand Down
42 changes: 29 additions & 13 deletions OWNd/message/base.py
Original file line number Diff line number Diff line change
Expand Up @@ -353,16 +353,33 @@ def where(self) -> str | None:
"""The 'where' ID of the subject of this message"""
return self._where # [1:] if self._where.startswith('#') else self._where

def _interface_and_where_params(self) -> tuple[str | None, list[str]]:
"""Split ``_where_param`` into ``(interface, remaining_where_params)``.

On WHO 0, 1, 2, 14, 15 and 1001, ``#4#IF`` starts at index 0.
On WHO 4 (excluding Dimension 22 split-unit ``3#Z#N`` addresses where
``Z`` can be ``4``), ``#4#IF`` sits either after a bare zone/central
address (``Z#4#IF``, length 2) or after an actuator/central-unit index
(``Z#N#4#IF`` / ``#0#C#4#IF``, length 3), so an actuator ``4`` address
``Z#4`` (length 1) is never misread as an incomplete interface token.
"""
if (
self._who in (0, 1, 2, 14, 15, 1001)
and len(self._where_param) > 1
and self._where_param[0] == "4"
):
return self._where_param[1], self._where_param[2:]
if self._who == 4 and self._dimension != 22:
if len(self._where_param) == 2 and self._where_param[0] == "4":
return self._where_param[1], []
if len(self._where_param) == 3 and self._where_param[1] == "4":
return self._where_param[2], [self._where_param[0]]
return None, self._where_param

@property
def interface(self) -> str | None:
"""The 'where' parameter corresponding to the bus interface of the subject of this message"""
return (
self._where_param[1]
if self._who in [0, 1, 2, 14, 15, 1001]
and len(self._where_param) > 1
and self._where_param[0] == "4"
else None
)
return self._interface_and_where_params()[0]

@property
def what(self) -> int | None:
Expand Down Expand Up @@ -420,12 +437,11 @@ def event_content(self) -> dict[str, Any]:
}
if self._where:
_event.update({"where": self._where})
if self.interface:
_event.update({"interface": self.interface})
if self._where_param and len(self._where_param) > 2:
_event.update({"where parameters": self._where_param[2:]})
elif self._where_param:
_event.update({"where parameters": self._where_param})
interface, where_params = self._interface_and_where_params()
if interface:
_event.update({"interface": interface})
if where_params:
_event.update({"where parameters": where_params})
# Explicit None checks: 0 is meaningful (what=0 is OFF, dimension=0
# is temperature) and must not be dropped from the event payload.
if self._what is not None:
Expand Down
25 changes: 19 additions & 6 deletions OWNd/message/heating.py
Original file line number Diff line number Diff line change
Expand Up @@ -360,15 +360,17 @@ def __init__(self, data: str) -> None:
self._type = None

where = self._where or "0"
_, where_params = self._interface_and_where_params()
# The frame grammar admits the wildcard WHERE ``*`` for every WHO
# (``*4*1**##``); it is no zone, so the event is zone 0, as a frame
# without a WHERE already was, instead of raising ValueError from int().
zone_digits = where[1:] if where.startswith("#") else where
self._zone = _ascii_int(zone_digits) or 0
# ``#0#N`` is zone N of a 4-zone central unit; ``0#N`` is actuator N
# of zone 0 (a pump the zones share), not zone N.
if self._zone == 0 and self._where_param and where.startswith("#"):
self._zone = int(self._where_param[0])
# of zone 0 (a pump the zones share), not zone N; ``#0#4#IF`` is ``#0``
# behind interface ``IF`` (``where_params`` is empty).
if self._zone == 0 and where_params and where.startswith("#"):
self._zone = int(where_params[0])
self._sensor = None
if self._zone > 99:
self._sensor = int(str(self._zone)[:1])
Expand Down Expand Up @@ -789,9 +791,7 @@ def __init__(self, data: str) -> None:
): # Actuator status
self._type = MESSAGE_TYPE_ACTION
self._is_active = self._dimension_value[0] in _actuator_active_states
self._actuator = (
self._where_param[0] if self._where_param else "1"
)
self._actuator = where_params[0] if where_params else "1"
_value = int(self._dimension_value[0])
if _value == 0:
self._human_readable_log = (
Expand Down Expand Up @@ -904,6 +904,11 @@ def message_type(self) -> str | None:
def zone(self) -> int:
return self._zone

@property
def actuator(self) -> str | None:
"""Actuator index of a WHO 4 Dimension 20 status event, else ``None``."""
return self._actuator

@property
def mode(self) -> str | None:
return self._mode_name
Expand Down Expand Up @@ -1601,6 +1606,14 @@ def central_status(cls, where: str = "#0") -> OWNHeatingCommand:
message._human_readable_log = f"Requesting Central Unit {where} status."
return message

@property
def actuator(self) -> str | None:
"""Actuator index of a WHO 4 Dimension 20 request or write, else ``None``."""
if self._dimension != 20:
return None
_, where_params = self._interface_and_where_params()
return where_params[0] if where_params else "1"

@property
def is_temperature_query(self) -> bool:
"""True if this message is a temperature dimension query (*#4*WHERE*0##)."""
Expand Down
67 changes: 65 additions & 2 deletions OWNd/profiles.py
Original file line number Diff line number Diff line change
Expand Up @@ -96,6 +96,19 @@ class GatewayProfile:
# WHO 18 reply-form frames (*#18*W*DIM*VAL##). True means acknowledged on
# the command session, not that the value is shown to reach the bus.
supports_who18_response_injection: bool | None = None
# WHO 4 thermoregulation request capabilities (None = unverified; True/False
# from own-firmware-oracle suites and live hardware traces):
# - supports_general_heating_status: general sweep *#4*0## (trace-corpus.tsv).
# - supports_heating_zone_status: per-zone status *#4*Z## (thermo-zone-requests,
# live multi-session traces MyHOME#629, #799, #866).
# - supports_heating_actuator_status: per-zone *#4*Z*20## (thermo-actuator.tsv).
# - supports_heating_humidity_request: per-zone *#4*Z*60## (thermo-zone-requests).
# - supports_interface_zone_requests: WHO 4 behind #4#II (thermo-zone-requests).
supports_general_heating_status: bool | None = None
supports_heating_zone_status: bool | None = None
supports_heating_actuator_status: bool | None = None
supports_heating_humidity_request: bool | None = None
supports_interface_zone_requests: bool | None = None
supported_who: tuple[int, ...] = DEFAULT_SUPPORTED_WHO
extra_features: tuple[str, ...] = ()
firmware_version: str | None = field(default=None, kw_only=True)
Expand Down Expand Up @@ -282,6 +295,10 @@ def __init__(self) -> None:
super().__init__(
model_name="F453",
command_queue_delay=0.15,
supports_general_heating_status=True,
supports_heating_actuator_status=False,
supports_heating_humidity_request=False,
supports_interface_zone_requests=False,
)


Expand Down Expand Up @@ -328,6 +345,10 @@ def __init__(
model_name="F453AV",
firmware_version=fw_str,
command_queue_delay=0.15,
supports_general_heating_status=True,
supports_heating_actuator_status=False,
supports_heating_humidity_request=False,
supports_interface_zone_requests=False,
supported_who=(
DEFAULT_SUPPORTED_WHO if has_cen_plus else _DEFAULT_WITHOUT_CEN_PLUS
),
Expand All @@ -338,9 +359,12 @@ def __init__(
class F454Profile(GatewayProfile):
"""The F454 Web Server (Legrand 003598).

Verified by the firmware oracle (``F454 020051``, ``results/F454/020051/oracle/full/``):
Verified by the firmware oracle (``F454 020051``, ``results/F454/020051/oracle/full/``)
and live hardware traces (``F454`` FW 1.0.34 in MyHOME#629, ``F454`` FW 2.0 in MyHOME#866):
packages ``openserver`` (HMAC-SHA2), ``bt_fls`` (WHO 1/2), ``bt_energia`` (WHO 3),
``bt_H4690`` (WHO 4), ``bt_cen`` (WHO 15/25), ``bt_difson`` (WHO 16, answering
``bt_H4690`` (WHO 4: drops ``*#4*0##`` and ``*#4*Z*60##``, expands ``*#4*Z##`` into four
SCS bus queries answered in ~1.3 s by both central-unit and standalone room thermostats,
and forwards ``*#4*Z*20##``), ``bt_cen`` (WHO 15/25), ``bt_difson`` (WHO 16, answering
``*#16*0*5##`` and 69 other WHO 16 requests with ``ack``/``out``), ``bt_multi``
(WHO 22), and ``bt_energy`` (WHO 18).
"""
Expand All @@ -354,6 +378,11 @@ def __init__(self) -> None:
supports_hmac=True,
supports_native_transitions=True,
supports_extended_frames=True,
supports_general_heating_status=False,
supports_heating_zone_status=True,
supports_heating_actuator_status=True,
supports_heating_humidity_request=False,
supports_interface_zone_requests=False,
)


Expand Down Expand Up @@ -437,6 +466,11 @@ def __init__(self) -> None:
supports_dimension_response_injection=False,
supports_who4_command_injection=True,
supports_who18_response_injection=True,
supports_general_heating_status=False,
supports_heating_zone_status=True,
supports_heating_actuator_status=True,
supports_heating_humidity_request=True,
supports_interface_zone_requests=False,
supported_who=tuple(
w
for w in DEFAULT_SUPPORTED_WHO
Expand Down Expand Up @@ -480,6 +514,10 @@ def __init__(self) -> None:
max_queue_size=100,
event_keepalive_interval=90,
supports_energy_instant_power=False,
supports_general_heating_status=False,
supports_heating_actuator_status=False,
supports_heating_humidity_request=False,
supports_interface_zone_requests=False,
supported_who=(
WHO_LIGHTING,
WHO_AUTOMATION,
Expand Down Expand Up @@ -521,6 +559,10 @@ def __init__(self) -> None:
event_keepalive_interval=90,
supports_energy_instant_power=False,
supports_audio=True,
supports_general_heating_status=True,
supports_heating_actuator_status=False,
supports_heating_humidity_request=False,
supports_interface_zone_requests=False,
supported_who=(
WHO_LIGHTING,
WHO_AUTOMATION,
Expand All @@ -545,6 +587,7 @@ def __init__(self) -> None:
max_queue_size=100,
audio_measured=False,
supports_extended_frames=True,
supports_general_heating_status=False,
extra_features=("Clock diagnostics",),
)

Expand All @@ -562,6 +605,12 @@ class MH202Profile(GatewayProfile):
every WHO 16 command: a live MH202 with an F441M matrix relays WHO 16
state frames (``*#16*41*1*1##``, ``*#16*41*1*6##``; MyHOME#669 trace),
and ``supported_who`` also decides which gateway owns those events.

WHO 4 per-zone status queries (``*#4*Z##``) are acknowledged by the
firmware oracle (``MH202 010024`` returns ``ack/out``, putting the 4 SCS
queries on the bus) and confirmed live on hardware (``MH202`` FW 1.0 in
MyHOME#866 comment 6641631764, answering all 5 frames across zones 1..5
in 160–250 ms).
"""

def __init__(self) -> None:
Expand All @@ -572,6 +621,11 @@ def __init__(self) -> None:
audio_measured=False,
supports_hmac=True,
supports_extended_frames=True,
supports_general_heating_status=False,
supports_heating_zone_status=True,
supports_heating_actuator_status=False,
supports_heating_humidity_request=False,
supports_interface_zone_requests=False,
supported_who=(*DEFAULT_SUPPORTED_WHO, WHO_ALARM),
)

Expand Down Expand Up @@ -650,6 +704,10 @@ def __init__(
super().__init__(
model_name="H4684",
firmware_version=fw_str,
supports_general_heating_status=False,
supports_heating_actuator_status=False,
supports_heating_humidity_request=False,
supports_interface_zone_requests=False,
supported_who=(
(*base_who, WHO_SOUND_DIFFUSION) if has_who22 else base_who
),
Expand Down Expand Up @@ -685,6 +743,11 @@ def __init__(self) -> None:
supports_hmac=True,
supports_native_transitions=True,
supports_extended_frames=True,
supports_general_heating_status=False,
supports_heating_zone_status=True,
supports_heating_actuator_status=True,
supports_heating_humidity_request=True,
supports_interface_zone_requests=False,
supported_who=tuple(
w
for w in DEFAULT_SUPPORTED_WHO
Expand Down
56 changes: 56 additions & 0 deletions tests/test_profiles.py
Original file line number Diff line number Diff line change
Expand Up @@ -711,3 +711,59 @@ def test_who16_stays_on_gateways_that_forward_it(model: str) -> None:
state frames from an F441M (``*#16*41*1*1##``, MyHOME#669), so it keeps
owning WHO 16 events."""
assert get_gateway_profile(model).supports_who(WHO_SOUND)


@pytest.mark.parametrize(
(
"model",
"general_status",
"zone_status",
"actuator_status",
"humidity_request",
"interface_requests",
),
[
# Oracle + live multi-session captures (MyHOME#629, #799, #866)
("F454", False, True, True, False, False),
("003598", False, True, True, False, False),
("F461", False, True, True, True, False),
("MyHomeServer1", False, True, True, True, False),
("MHS1", False, True, True, True, False),
("MH202", False, True, False, False, False),
("03535", False, True, False, False, False),
("003535", False, True, False, False, False),
# Gateways supporting general sweep *#4*0## (zone_status left None / unverified)
("F453", True, None, False, False, False),
("F453AV", True, None, False, False, False),
("MH200N", True, None, False, False, False),
# Single-session / unmeasured in WHO 4 oracle (zone_status left None for caller policy)
("F455", None, None, None, None, None),
# Single-session / scenario gateways in oracle (zone_status left None for caller policy)
("H4684", False, None, False, False, False),
("H/L4684", False, None, False, False, False),
("MH200", False, None, False, False, False),
# Live MH201 sweep (#466: *#4*0## gets no zone reply; not in oracle)
("MH201", False, None, None, None, None),
# Unmeasured in WHO 4 oracle / captures
("F452", None, None, None, None, None),
("F452V", None, None, None, None, None),
("H4890", None, None, None, None, None),
("UnknownModel", None, None, None, None, None),
],
)
def test_who4_heating_capability_flags(
model: str,
general_status: bool | None,
zone_status: bool | None,
actuator_status: bool | None,
humidity_request: bool | None,
interface_requests: bool | None,
) -> None:
"""Verify declarative WHO 4 request capability flags across gateway profiles."""
profile = get_gateway_profile(model)
assert profile.supports_general_heating_status is general_status
assert profile.supports_heating_zone_status is zone_status
assert profile.supports_heating_actuator_status is actuator_status
assert profile.supports_heating_humidity_request is humidity_request
assert profile.supports_interface_zone_requests is interface_requests