93 changes: 86 additions & 7 deletions custom_components/myhome/climate.py
Original file line number Diff line number Diff line change
Expand Up @@ -681,11 +681,15 @@ def __init__(
self._attr_current_humidity: float | None = None
self._target_temperature: float | None = None
self._local_offset: float = 0
self._local_offset_reported = False
self._knob_pos: str = "UNKNOWN"
self._local_target_temperature: float | None = None
# True while _local_target_temperature is the zone's own dimension 12 report (the
# setpoint in force, offset included): dimension 14 and 13 frames then leave it alone.
self._local_target_reported = False
self._dim12_at: float | None = None
self._dim14_at: float | None = None
self._written_target_temperature: tuple[float, float] | None = None
self._current_temperature_restored = False
# True while the setpoint / the mode are what Home Assistant saved, not what the zone
# said since the restart: the silent-zone poll (#466) does not take them for a report.
Expand Down Expand Up @@ -1573,12 +1577,60 @@ def _effective_nominal_temperature(self) -> float | None:
return self._local_target_temperature - self._local_offset
return None

def _derive_local_offset(self, local_target: float | None, nominal_target: float | None) -> bool:
"""Derive the knob offset from a paired Dimension 12 and Dimension 14 when Dimension 13 is absent (#466)."""
if (
self._local_offset_reported
or self._attr_hvac_mode in (None, HVACMode.OFF)
or local_target is None
or nominal_target is None
):
return False
diff = round(local_target - nominal_target, 1)
if not (-3.0 <= diff <= 3.0 and float(diff).is_integer()):
return False
offset = int(diff)
if offset == 0 and self._local_offset == 0:
return False
self._local_offset = offset
self._knob_pos = "0" if offset == 0 else f"{offset:+d}"
return True

def _reconcile_local_target(self) -> None:
"""Update nominal setpoint and derived knob offset from a Dimension 12 report (#466)."""
now = time.monotonic()
written = self._written_target_temperature
self._written_target_temperature = None
if written is not None and now - written[1] <= _PROTECTION_FRAME_WINDOW:
self._derive_local_offset(self._local_target_temperature, written[0])
self._dim12_at = None
self._dim14_at = None
elif self._dim14_at is not None and now - self._dim14_at <= _PROTECTION_FRAME_WINDOW:
self._derive_local_offset(self._local_target_temperature, self._target_temperature)
self._dim12_at = None
self._dim14_at = None
self._target_temperature = (
self._local_target_temperature - self._local_offset
if self._local_target_temperature is not None
else None
)

def _hydrate_nominal_from_local(self, prev_mode: HVACMode | None) -> None:
"""Promote an initial Dimension 12/14 reading once the zone is known to be active (#819)."""
if self._central or prev_mode is not None or self._attr_hvac_mode in (None, HVACMode.OFF):
return
if self._target_temperature is None and self._local_target_temperature is not None:
self._target_temperature = self._local_target_temperature - self._local_offset
if self._local_target_temperature is not None and self._local_target_reported:
if (
self._written_target_temperature is None
and self._target_temperature is not None
and self._dim14_at is not None
and time.monotonic() - self._dim14_at <= _PROTECTION_FRAME_WINDOW
):
self._derive_local_offset(self._local_target_temperature, self._target_temperature)
self._dim12_at = None
self._dim14_at = None
else:
self._reconcile_local_target()
elif (
self._local_target_temperature is None
and self._target_temperature is not None
Expand Down Expand Up @@ -1808,6 +1860,7 @@ async def async_set_temperature(self, **kwargs: Any) -> None:
# The write's echo decides what is shown next: dimension 12 where the gateway reports
# the setpoint in force (F461, MyHomeServer1), else the commanded dimension 14.
self._local_target_reported = False
self._written_target_temperature = (target_temperature, time.monotonic())

def _dimension_3_is_protection(self, message: OWNHeatingEvent) -> bool:
"""Whether a dimension 12/14 frame may be a protection setpoint rather than the nominal one.
Expand All @@ -1833,6 +1886,8 @@ def _restore_nominal_before_protection(self) -> None:
previous nominal back (#383).
"""
remembered, self._nominal_before_dim12 = self._nominal_before_dim12, None
self._dim12_at = None
self._dim14_at = None
if remembered is not None and time.monotonic() - remembered[1] <= _PROTECTION_FRAME_WINDOW:
self._target_temperature = remembered[0]

Expand All @@ -1846,6 +1901,8 @@ def _show_nominal(self) -> None:
return
self._local_target_temperature = self._target_temperature + self._local_offset
self._local_target_reported = False
self._dim12_at = None
self._dim14_at = None

def _apply_zone_state(self, message: OWNHeatingEvent) -> None:
"""Dimension 7: the zone's operating state, and its setpoint in state 'setpoint'.
Expand Down Expand Up @@ -2042,6 +2099,8 @@ def handle_event(self, message: OWNHeatingEvent) -> None:
)
self._attr_native_current_temperature = message.main_temperature
self._current_temperature_restored = False
self._dim12_at = None
self._dim14_at = None
elif message.message_type == MESSAGE_TYPE_MAIN_HUMIDITY:
LOGGER.debug(
"%s %s",
Expand All @@ -2059,7 +2118,23 @@ def handle_event(self, message: OWNHeatingEvent) -> None:
)
self._target_temperature = message.set_temperature
self._target_temperature_restored = False
self._written_target_temperature = None
now = time.monotonic()
is_protection_or_off = self._dimension_3_is_protection(message)
if (
not is_protection_or_off
and self._dim12_at is not None
and now - self._dim12_at <= _PROTECTION_FRAME_WINDOW
):
self._derive_local_offset(self._local_target_temperature, self._target_temperature)
self._dim12_at = None
self._dim14_at = None
else:
self._dim14_at = (
now
if self._target_temperature is not None and self._attr_hvac_mode != HVACMode.OFF
else None
)
# Dimension 14 is the commanded setpoint. The thermostat can regulate to another one
# (F461: 14 = 21.0 while 12 = 23.5), so a dimension 12 report stays what is shown.
if not is_protection_or_off and not self._local_target_reported:
Expand All @@ -2075,6 +2150,9 @@ def handle_event(self, message: OWNHeatingEvent) -> None:
message.human_readable_log,
)
self._local_offset = message.local_offset if message.local_offset is not None else 0
self._local_offset_reported = True
self._dim12_at = None
self._dim14_at = None
if message.local_control_state in (LOCAL_CONTROL_UNKNOWN, None):
self._knob_pos = "UNKNOWN"
elif message.local_control_state == LOCAL_CONTROL_OFFSET:
Expand Down Expand Up @@ -2103,15 +2181,16 @@ def handle_event(self, message: OWNHeatingEvent) -> None:
)
self._local_target_temperature = message.local_set_temperature
self._local_target_reported = self._local_target_temperature is not None
self._dim12_at = (
time.monotonic()
if self._local_target_reported and self._attr_hvac_mode != HVACMode.OFF
else None
)
self._target_temperature_restored = False
is_protection_or_off = self._dimension_3_is_protection(message)
if not is_protection_or_off:
self._remember_nominal()
self._target_temperature = (
self._local_target_temperature - self._local_offset
if self._local_target_temperature is not None
else None
)
self._reconcile_local_target()
elif message.message_type == MESSAGE_TYPE_SEASON:
# *4*1*Z## / *4*0*Z## is the zone operation mode frame: the zone
# (or the central unit) runs in the heating / conditioning season
Expand Down