215 changes: 189 additions & 26 deletions custom_components/myhome/climate.py
Original file line number Diff line number Diff line change
Expand Up @@ -22,6 +22,7 @@
from homeassistant.helpers import entity_registry as er
from homeassistant.helpers.dispatcher import async_dispatcher_connect, async_dispatcher_send
from homeassistant.helpers.entity_platform import AddEntitiesCallback
from homeassistant.helpers.event import async_call_later
from homeassistant.helpers.restore_state import DATA_RESTORE_STATE
from OWNd.message import (
CLIMATE_MODE_AUTO,
Expand Down Expand Up @@ -133,6 +134,20 @@ def _central_diagnostic_what(message: Any) -> int | None:
# frame equal to the command that arrives later, from the central unit or another client,
# is still taken as a report.
_CENTRAL_ECHO_WINDOW = 0.1
# While the command is still queued or in flight (its ``written`` future not done) the echo has
# no deadline yet; past this time the gateway's command pool has given up on it
# (gateway.PACED_WRITE_TIMEOUT), so the echo is no longer expected.
_CENTRAL_ECHO_PENDING_LIMIT = 60.0
# The 3550's status reply is its mode, then *4*20*#0## / *4*21*#0## (remote control), then
# only the optional flags that are active (*4*22..24*#0##, *4*30*#0##, *4*31*#0##; WHO 4 p. 5,
# p. 24-25). No frame says a flag is clear, so a flag that does not follow a 20 / 21 frame
# within this time is clear. Live F461 and F455, 2026-11-08 / 11-09: 31 came 0-1 ms after 21.
_CENTRAL_FLAGS_SETTLE = 1.0
_CENTRAL_FLAG_WHATS = (22, 23, 24, 30, 31)
# A generic *4*310/311*#Z## frame waits this long for the zone's seasonal status. An F455 put its
# synthetic *4*311*#4## 59-61 ms before *4*210*#4## / *4*203*#4## / *4*202*#4## (18 of 18, live
# 2026-11-08 / 11-09); a generic frame with no seasonal status after it is the zone's state (WHO 4 p. 9).
_GENERIC_ZONE_FRAME_HOLD = 0.5
_CONDITIONING_SEASONS = (SEASON_CONDITIONING, "cooling")

# How long the fan speed poll waits for the one-shot dimension 19 answer (*#4*Z*19##,
Expand Down Expand Up @@ -638,7 +653,7 @@ def __init__(
self._central_operation: str | None = None
# Central unit: Home Assistant's last command and when its local echo stops being expected,
# and the echo frame once seen (the same frame object can be delivered more than once).
self._central_echo: tuple[str, float] | None = None
self._central_echo: tuple[str, float | None, float] | None = None
self._central_echo_seen: object | None = None
self._program: int | None = None
self._holiday_days: int | None = None
Expand All @@ -665,6 +680,13 @@ def __init__(
self._at_least_one_probe_manual: bool = False
self._failure_detected: bool = False
self._battery_fault: bool = False
# The optional flags seen since the last 20 / 21 frame, and the timer that clears the others.
self._central_flags_seen: set[int] = set()
self._central_flags_unsub: Any = None
# A generic *4*310/311*#Z## frame held back until the zone's seasonal status shows whether
# it was only a prelude, the timer that applies it otherwise, and the frame being applied.
self._generic_zone_frame_unsub: Any = None
self._generic_zone_frame_release: object | None = None

self._attr_hvac_mode: HVACMode | None = None
self._attr_hvac_action: HVACAction | None = None
Expand Down Expand Up @@ -1174,7 +1196,10 @@ async def async_added_to_hass(self) -> None:
if target_hass is not None:
if self._central:
self._clear_unresponsive_issue()
elif self._standalone_config is not True:
self.async_on_remove(self._cancel_central_flag_cycle)
else:
self.async_on_remove(self._cancel_generic_zone_frame)
if not self._central and self._standalone_config is not True:
self.async_on_remove(
async_dispatcher_connect(
target_hass,
Expand Down Expand Up @@ -1398,21 +1423,58 @@ def _hydrate_nominal_from_local(self, prev_mode: HVACMode | None) -> None:
):
self._local_target_temperature = self._target_temperature + self._local_offset

def _reset_central_status_flags(self) -> None:
"""Reset optional central unit (#0) flags at the start of a new mode/status burst (#819).

On ``*#4*#0##`` (and unsolicited ``#0`` status bursts), the BTicino 3550 emits its
operating mode frame first (``*4*1101*#0##``, ``*4*102*#0##``, etc.), followed by
``WHAT 20``/``21`` and whichever optional fault/probe flags (``WHAT 22, 23, 24, 30, 31``)
are currently active. Optional flags have no separate all-clear code and are simply
omitted once resolved.
def _begin_central_flag_cycle(self) -> None:
"""Start collecting the 3550's optional flags after its remote-control frame (#819).

On ``*#4*#0##`` (and unsolicited ``#0`` bursts) the 3550 sends its operating mode,
``WHAT 20``/``21``, then whichever optional flags (``WHAT 22, 23, 24, 30, 31``) are
active (WHO 4 p. 24-25). A flag has no all-clear code; it is omitted once resolved.
The flags are not cleared here: clearing them at the start of the burst wrote
``battery_fault`` False and, 2 ms later, True on every reply of a 3550 without a
battery (live F461 + F455, 2026-11-09). A flag still missing when the burst has
settled is cleared by ``_settle_central_flags``. A second copy of the same frame
(climate and sensor platform routing) does not restart an open cycle.
"""
self._at_least_one_probe_off = False
self._at_least_one_probe_antifreeze = False
self._at_least_one_probe_manual = False
self._failure_detected = False
self._battery_fault = False
self._clear_fault(FaultKind.CENTRAL_BATTERY_FAULT)
if self._central_flags_unsub is not None:
return
self._central_flags_seen = set()
if self.hass is None or self.platform is None or not self.entity_id:
# Not live yet (discovery seed, restore): nothing is written in between, so there is
# no flip to avoid; the flags of this burst follow directly.
self._settle_central_flags(None)
return
self._central_flags_unsub = async_call_later(self.hass, _CENTRAL_FLAGS_SETTLE, self._settle_central_flags)

@callback
def _settle_central_flags(self, _now: Any) -> None:
"""Clear the optional central flags the last burst did not report."""
self._central_flags_unsub = None
seen = self._central_flags_seen
before = self._central_flag_values()
self._at_least_one_probe_off = 22 in seen
self._at_least_one_probe_antifreeze = 23 in seen
self._at_least_one_probe_manual = 24 in seen
self._failure_detected = 30 in seen
self._battery_fault = 31 in seen
if not self._battery_fault:
self._clear_fault(FaultKind.CENTRAL_BATTERY_FAULT)
if self._central_flag_values() != before:
self._publish_state()

def _central_flag_values(self) -> tuple[bool, ...]:
return (
self._at_least_one_probe_off,
self._at_least_one_probe_antifreeze,
self._at_least_one_probe_manual,
self._failure_detected,
self._battery_fault,
)

@callback
def _cancel_central_flag_cycle(self) -> None:
if self._central_flags_unsub is not None:
self._central_flags_unsub()
self._central_flags_unsub = None

async def async_set_hvac_mode(self, hvac_mode: HVACMode) -> None:
"""Set new target hvac mode."""
Expand All @@ -1431,13 +1493,26 @@ async def async_set_hvac_mode(self, hvac_mode: HVACMode) -> None:
where=self._where,
mode=cmd_mode,
)
# Set before sending: the echo can arrive while send() is still awaited.
self._central_echo = (str(command), time.monotonic() + _CENTRAL_ECHO_WINDOW)
# Armed before sending, without a deadline: the echo can arrive while the frame
# waits in the command pool or while send() is still awaited. The window starts
# when the frame is written (the ``written`` future's result), not now, so a busy
# CommandWorkerPool does not push the echo out of it.
frame = str(command)
armed_at = time.monotonic()
self._central_echo = (frame, None, armed_at)
try:
await self._gateway_handler.send(command)
written: Any = await self._gateway_handler.send(command)
except BaseException:
self._central_echo = None
raise
if isinstance(written, asyncio.Future):

def _on_written(future: "asyncio.Future[float]", armed_at: float = armed_at) -> None:
self._anchor_central_echo(armed_at, future)

written.add_done_callback(_on_written)
else:
self._anchor_central_echo(armed_at, None)
if hvac_mode in (HVACMode.HEAT, HVACMode.COOL) and self._where.removeprefix("4-") in ("#0", "0"):
# *4*1*#0## / *4*0*#0## only change the season (WHO 4 p. 5). The 3550
# answers with the operating mode it is in, e.g. *4*102*#0## antifreeze,
Expand Down Expand Up @@ -1644,6 +1719,28 @@ def _apply_zone_state(self, message: OWNHeatingEvent) -> None:
):
self._show_nominal()

@callback
def _anchor_central_echo(self, armed_at: float, written: "asyncio.Future[float] | None") -> None:
"""Start the echo window at the time the command was written (MyHOMEGatewayHandler.send).

The future resolves to the monotonic time taken just before the frame went on the
socket; it is cancelled when the frame is never written, and then no echo comes.
Without a future (a gateway double, a delegated send) the window starts now. Only the
command armed at ``armed_at`` is anchored: a later command, even the same frame, keeps
waiting for its own write.
"""
echo = self._central_echo
if echo is None or echo[2] != armed_at:
return
frame = echo[0]
if written is None:
self._central_echo = (frame, time.monotonic() + _CENTRAL_ECHO_WINDOW, echo[2])
return
if written.cancelled() or written.exception() is not None:
self._central_echo = None
return
self._central_echo = (frame, float(written.result()) + _CENTRAL_ECHO_WINDOW, echo[2])

@callback
def _is_own_central_echo(self, message: OWNHeatingEvent) -> bool:
"""Whether ``message`` is the gateway handing back Home Assistant's own central command.
Expand All @@ -1663,8 +1760,11 @@ def _is_own_central_echo(self, message: OWNHeatingEvent) -> bool:
echo = self._central_echo
if echo is None:
return False
frame, deadline = echo
if time.monotonic() > deadline:
frame, deadline, armed_at = echo
now = time.monotonic()
if (deadline is None and now - armed_at > _CENTRAL_ECHO_PENDING_LIMIT) or (
deadline is not None and now > deadline
):
self._central_echo = None
return False
if str(message) != frame:
Expand All @@ -1686,6 +1786,63 @@ def _is_central_addressed_mode_frame(self, message: OWNHeatingEvent) -> bool:
return False
return is_central_thermo_where(message)

def _is_generic_central_zone_frame(self, message: OWNHeatingEvent) -> bool:
"""Whether a ``*4*310*#Z##`` / ``*4*311*#Z##`` frame reaches a zone of the central unit.

WHO 4 p. 9 lists 310 / 311 (manual / automatic generic) both as the command that sets a
zone of the central and as a monitor frame. The 3550 reports its zones' state with the
season in the code: ``*4*111*#1##`` for a zone in automatic heating, also as its answer to
``*4*311*#1##`` (MH200N, #466), ``*4*110*#3##`` (F454, #697), ``*4*210*#4##`` (F461, 0 generic
frames in 525, 2026-11-08 / 11-09). An F455 and an MH201 put a generic ``*4*311*#Z##`` on
their event session right before the zone's real status (``*4*210*#4##`` 59 ms later on the
F455, ``*4*110*#4##`` on the MH201): live F455, 2026-11-09 07:45:02, at every quarter-hour
push of the 3550, where the F461 shows ``*#4*#4*14*0240*2##`` instead. Taken as the zone's
state it turned the zone AUTO and back every 15 minutes. So the generic frame is held
(``_GENERIC_ZONE_FRAME_HOLD``): a seasonal status of the zone that follows replaces it, and
only a generic frame with none after it is taken as the zone's state.
"""
if self._central or message.message_type != MESSAGE_TYPE_MODE:
return False
if not is_central_thermo_where(message):
return False
raw = str(message) # a MESSAGE_TYPE_MODE frame is *4*WHAT*WHERE##
where = raw.split("*")[3] if raw.count("*") >= 3 else ""
if where.removeprefix("#").split("#", 1)[0] == "0":
return False
return raw.split("*")[2] in ("310", "311")

def _hold_generic_zone_frame(self, message: OWNHeatingEvent) -> bool:
"""Hold a generic ``#Z`` frame until the zone's seasonal status shows it was a prelude.

Returns False when the entity is not live yet (nothing to hold it on); the frame is
then handled at once, as before.
"""
if self.hass is None or self.platform is None or not self.entity_id:
return False
self._cancel_generic_zone_frame()
LOGGER.debug(
"%s %s: generic mode frame for %s via the central unit; waiting for its seasonal status",
self._gateway_handler.log_id,
message,
self._display_name,
)

@callback
def _apply(_now: Any) -> None:
self._generic_zone_frame_unsub = None
self._generic_zone_frame_release = message
self.handle_event(message)

self._generic_zone_frame_unsub = async_call_later(self.hass, _GENERIC_ZONE_FRAME_HOLD, _apply)
return True

@callback
def _cancel_generic_zone_frame(self) -> None:
"""Drop a held generic frame: the zone's own status came, or the entity goes away."""
if self._generic_zone_frame_unsub is not None:
self._generic_zone_frame_unsub()
self._generic_zone_frame_unsub = None

def handle_event(self, message: OWNHeatingEvent) -> None:
"""Handle an event message."""
if self._central and self._is_own_central_echo(message):
Expand All @@ -1705,6 +1862,13 @@ def handle_event(self, message: OWNHeatingEvent) -> None:
self._display_name,
)
return
if message is self._generic_zone_frame_release:
self._generic_zone_frame_release = None
elif self._is_generic_central_zone_frame(message):
if self._hold_generic_zone_frame(message):
return
elif message.message_type in (MESSAGE_TYPE_MODE, MESSAGE_TYPE_MODE_TARGET, MESSAGE_TYPE_SEASON):
self._cancel_generic_zone_frame()
if message.message_type == MESSAGE_TYPE_MAIN_TEMPERATURE:
LOGGER.debug(
"%s %s",
Expand Down Expand Up @@ -1800,8 +1964,6 @@ def handle_event(self, message: OWNHeatingEvent) -> None:
# same mode (live F455 + F461, 2026-11-08), and a stale restored AUTO is replaced.
# An AUTO the zone itself reported (a MyHomeServer1 schedule, Dimension 7 context
# automatic) is not cancelled: the season frame that follows it is its season.
if self._central:
self._reset_central_status_flags()
standalone_mode = self._standalone and not (
self._attr_hvac_mode == HVACMode.AUTO and not self._hvac_mode_restored
)
Expand Down Expand Up @@ -1839,8 +2001,6 @@ def handle_event(self, message: OWNHeatingEvent) -> None:
)
self._follow_season_change(previous_season)
elif message.message_type == MESSAGE_TYPE_MODE:
if self._central:
self._reset_central_status_flags()
self._hvac_mode_restored = False # the zone itself says what it runs in
prev_mode = self._attr_hvac_mode
previous_season = self._season
Expand Down Expand Up @@ -1924,7 +2084,6 @@ def handle_event(self, message: OWNHeatingEvent) -> None:
)
elif message.message_type == MESSAGE_TYPE_MODE_TARGET:
if self._central:
self._reset_central_status_flags()
self._central_operation = None
self._hvac_mode_restored = False
prev_mode = self._attr_hvac_mode
Expand Down Expand Up @@ -2128,6 +2287,10 @@ def handle_event(self, message: OWNHeatingEvent) -> None:
self._gateway_handler.log_id,
getattr(message, "human_readable_log", str(message)),
)
if diag_what in (20, 21):
self._begin_central_flag_cycle()
elif diag_what in _CENTRAL_FLAG_WHATS:
self._central_flags_seen.add(diag_what)
if diag_what == 20:
self._remote_control = "disabled"
self._report_fault(FaultKind.CENTRAL_REMOTE_CONTROL_DISABLED, code="20")
Expand Down