You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
No native PrimAITE run can execute from this distribution. On dev (0272949):
pyproject.toml L22 requires Python >=3.12.
src/raes_adapters/primaite/backend/driver.py L13-18: "That worker boundary is not implemented here, and the qualified runtime is CPython 3.11 while this distribution requires 3.12+." The live driver verifies the source identity and then fails closed (_RUNTIME_UNQUALIFIED, L32-37), so a composed live run fails at provisioning on every interpreter the package installs on.
The docstring names the two prerequisites for a live run: a separately reviewed worker-process boundary (the child gets its own launch environment instead of this process mutating HOME or the working directory) and bounded CPython 3.12 qualification evidence.
The primaite extra is empty (pyproject.toml L44-51) because the PrimAITE v4.0.0 pins conflict with the single lock, so no CI job installs PrimAITE. noxfile.py L328-332 composes the PR conformance bundle with an injected driver and native_conformance false.
The native fixture lane designed in #101 and the source-native half of the baseline reproduction (#44) both need a live driver.
Implementing the driver changes the runtime and package, which the 2026-08-13 hold on #88 does not allow until OpenRAE/rae#1023 is settled.
Scope
Implement the worker-process driver boundary described in driver.py, with the selected PrimAITE source installed in the worker's own environment.
Produce bounded qualification evidence for the interpreter the worker runs PrimAITE on, and update the qualified-runtime gate to match.
Add a CI job that installs the pinned PrimAITE source and runs the native smoke through the worker.
Done when
A live PrimAITE run through the worker boundary passes the qualified-runtime gate and completes an episode on a supported interpreter.
The qualification record names the interpreter and the evidence that qualifies it.
A CI job installs PrimAITE and runs the native smoke.
Activity