Calibrated 2-D Gaussian filtering rejects a singleton assembled SITE stack #980
Observed in the fresh R0010_FRESH25_94 task-only author, receiving25 on isolated display94. The original source has a 2-D calibrated plane; processing assembles SITE (one selected site), group_by NONE. Registered cellprofiler_gaussian_filter receives an assembled rank3 payload and fails: Cannot project 2-D source voxel spacing onto 3-D data. The source and failure remain preserved at /home/ts/wt/openhcs-issue-batch-20260929/next-h003-retina-fresh25-rotation-20261006/R0010_FRESH25_94/author-workspace/output/preprocess01-technical02.py and runtime/mcp.stdout (failure around16118). The author continued independently using a typed plane custom callable; its scientific run must not be replayed or hotpatched.
Current source: GaussianFilterModule and gaussian_filter in openhcs/processing/backends/cellprofiler/gaussian_filter.py. The callable is FLEXIBLE with ImagePayloadExecutionMode.FULL_STACK and obtains spacing_for_ndim(pixel_data.ndim), without distinguishing an assembled nonspatial SITE axis from physical Z. Actual execution route traverses function_contract_execution and its stack owner. Fix through existing declared axis/payload/execution owners, not a second Gaussian implementation, default spacing or per-call rank switch. Do not relax SourceVoxelSpacing validation or assign invented Z calibration to SITE.
Acceptance: calibrated 2-D plane through singleton SITE assembly succeeds; multiple independent sites are not smoothed across each other; true calibrated anisotropic Z stacks retain volumetric Gaussian semantics and sigma/spacing conversion; output geometry, source provenance and spacing remain intact. Exercise the registered installed MCP compile/execute path in an engineering destination after the coherent source fix. No reference/held-out data or science feedback is needed. Parent is assigning Planck this independent source investigation and draft PR; existing fleet owners remain unchanged. Existing closed issue419 concerns a different shape/distance route, not this Gaussian surface.
Taking source and installed acceptance ownership. The failing Gaussian FULL_STACK call uses total payload rank as physical spacing rank; the existing source-spatial domain already distinguishes intrinsic YX/ZYX from assembled source cohorts. Investigating that owner projection and channel exclusion before editing. Current #973/#977 files do not overlap the proposed runtime-image metadata/Gaussian methods. Original run, failure and installed receiving25 remain unchanged.
Fixed by merged PR #981. Independently verified remote main contains the reviewed head and merge. Installed receiving28 public MCP compile/execute passed on one A01 well with three independent SITE planes and declared physical YX spacing (0.5,0.75): runtime and persisted planes exactly match independent per-site expectations, sites2/3 remain zero, no fabricated physical Z. Installed production bytes match the merged head; complete postwriter journal seals pass and exact owned processes are closed. Receipt: engineering-gaussian-axis-outcome28-20261006/public95-path02/INSTALLED-GAUSSIAN981-ACCEPTANCE01.rst. This is calibrated-axis synthetic acceptance, not a biological segmentation claim; no hosted CI hold.
Activity
trissim commentedon Oct 6, 2026
Taking source and installed acceptance ownership. The failing Gaussian FULL_STACK call uses total payload rank as physical spacing rank; the existing source-spatial domain already distinguishes intrinsic YX/ZYX from assembled source cohorts. Investigating that owner projection and channel exclusion before editing. Current #973/#977 files do not overlap the proposed runtime-image metadata/Gaussian methods. Original run, failure and installed receiving25 remain unchanged.
trissim commentedon Oct 6, 2026
Fixed by merged PR #981. Independently verified remote main contains the reviewed head and merge. Installed receiving28 public MCP compile/execute passed on one A01 well with three independent SITE planes and declared physical YX spacing (0.5,0.75): runtime and persisted planes exactly match independent per-site expectations, sites2/3 remain zero, no fabricated physical Z. Installed production bytes match the merged head; complete postwriter journal seals pass and exact owned processes are closed. Receipt: engineering-gaussian-axis-outcome28-20261006/public95-path02/INSTALLED-GAUSSIAN981-ACCEPTANCE01.rst. This is calibrated-axis synthetic acceptance, not a biological segmentation claim; no hosted CI hold.