Skip to content

Using ANCOMBC2 to test Correlations with Serum Markers #218

Closed

Description

@JLammons14

I had a question about the application of ANCOMBC2

I am curious to know if it would be appropriate to use ANCOMBC2 to test the correlation between microbial abundance and serum marker concentration. I ask this because the serum marker I am interested in would be unlikely to effect the composition of the microbiome, so I wasn't sure if its inclusion in the analysis would through off the bias correction.

I am also wanted to know if I could use the bias corrected log abundance from prior analysis that included biologically relevant confounders and group variables for downstream linear modeling?

Thanks

Activity

  1. FrederickHuangLin commented on Nov 10, 2023

    @FrederickHuangLin
    Member

    Hello @JLammons14,

    I'm not entirely sure about the structure of the serum marker data you're working with. If it's compositional in nature, you might want to consider using the secom function within the ANCOMBC package to obtain correlations. On the other hand, if the serum marker data doesn't follow a compositional structure, you may need to derive correlations by employing bias-corrected abundance for the microbiome data, along with suitable transformations for the serum marker data.

    Best regards,
    Frederick

  2. locked and limited conversation to collaborators on Nov 10, 2023
  3. converted this issue into a discussion #223 on Nov 10, 2023
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment