266 changes: 14 additions & 252 deletions luxtronik/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -5,269 +5,31 @@
from __future__ import annotations

import logging
import socket
import struct
import time

from luxtronik.common import get_host_lock
from luxtronik.calculations import Calculations
from luxtronik.parameters import Parameters
from luxtronik.visibilities import Visibilities
from luxtronik.discover import discover # noqa: F401
from luxtronik.constants import (

from luxtronik.cfi import (
LUXTRONIK_DEFAULT_PORT,
LUXTRONIK_PARAMETERS_WRITE,
LUXTRONIK_PARAMETERS_READ,
LUXTRONIK_CALCULATIONS_READ,
LUXTRONIK_VISIBILITIES_READ,
LUXTRONIK_SOCKET_READ_SIZE_INTEGER,
LUXTRONIK_SOCKET_READ_SIZE_CHAR,
Calculations, # noqa: F401
Parameters, # noqa: F401
Visibilities, # noqa: F401
LuxtronikData,
LuxtronikSocketInterface,
)
from luxtronik.shi import resolve_version
from luxtronik.shi.modbus import LuxtronikModbusTcpInterface
from luxtronik.shi.holdings import Holdings
from luxtronik.shi.interface import LuxtronikSmartHomeData, LuxtronikSmartHomeInterface
from luxtronik.shi.constants import (
from luxtronik.shi import (
LUXTRONIK_DEFAULT_MODBUS_PORT,
LuxtronikModbusTcpInterface,
Holdings, # noqa: F401
Inputs, # noqa: F401
LuxtronikSmartHomeData,
LuxtronikSmartHomeInterface,
resolve_version,
)

# endregion Imports

LOGGER = logging.getLogger("Luxtronik")

# Wait time (in seconds) after writing parameters to give controller
# some time to re-calculate values, etc.
WAIT_TIME_AFTER_PARAMETER_WRITE = 1


class LuxtronikData:
"""
Collection of parameters, calculations and visiblities.
Also provide some high level access functions to their data values.
"""

def __init__(self, parameters=None, calculations=None, visibilities=None, safe=True):
self.parameters = Parameters(safe) if parameters is None else parameters
self.calculations = Calculations() if calculations is None else calculations
self.visibilities = Visibilities() if visibilities is None else visibilities

def get_firmware_version(self):
return self.calculations.get_firmware_version()


class LuxtronikSocketInterface:
"""Luxtronik read/write interface via socket."""

def __init__(self, host, port=LUXTRONIK_DEFAULT_PORT):
# Acquire a lock object for this host to ensure thread safety
self._lock = get_host_lock(host)

self._host = host
self._port = port
self._socket = None

@property
def lock(self):
return self._lock

def _with_lock_and_connect(self, func, *args, **kwargs):
"""
Decorator around various read/write functions to connect first.

This method is essentially a wrapper for the _read() and _write() methods.
Locking is being used to ensure that only a single socket operation is
performed at any point in time. This helps to avoid issues with the
Luxtronik controller, which seems unstable otherwise.
"""
with self.lock:
try:
ret_val = None
with socket.create_connection((self._host, self._port)) as sock:
self._socket = sock
LOGGER.info("Connected to Luxtronik heat pump %s:%s", self._host, self._port)
ret_val = func(*args, **kwargs)
except socket.gaierror as e:
LOGGER.error("Failed to connect to Luxtronik heat pump %s:%s. %s.",
self._host, self._port, f"Address-related error: {e}")
except socket.timeout as e:
LOGGER.error("Failed to connect to Luxtronik heat pump %s:%s. %s.",
self._host, self._port, f"Connection timed out: {e}")
except ConnectionRefusedError as e:
LOGGER.error("Failed to connect to Luxtronik heat pump %s:%s. %s.",
self._host, self._port, f"Connection refused: {e}")
except OSError as e:
LOGGER.error("Failed to connect to Luxtronik heat pump %s:%s. %s.",
self._host, self._port, f"OS error during connect: {e}")
except Exception as e:
LOGGER.error("Failed to connect to Luxtronik heat pump %s:%s. %s.",
self._host, self._port, f"Unknown exception: {e}")
self._socket = None
return ret_val

def read(self, data=None):
"""
All available data will be read from the heat pump
and integrated to the passed data object.
This data object is returned afterwards, mainly for access to a newly created.
"""
if data is None:
data = LuxtronikData()
return self._with_lock_and_connect(self._read, data)

def read_parameters(self, parameters=None):
"""
Read parameters from heat pump and integrate them to the passed dictionary.
This dictionary is returned afterwards, mainly for access to a newly created.
"""
if parameters is None:
parameters = Parameters()
return self._with_lock_and_connect(self._read_parameters, parameters)

def read_calculations(self, calculations=None):
"""
Read calculations from heat pump and integrate them to the passed dictionary.
This dictionary is returned afterwards, mainly for access to a newly created.
"""
if calculations is None:
calculations = Calculations()
return self._with_lock_and_connect(self._read_calculations, calculations)

def read_visibilities(self, visibilities=None):
"""
Read visibilities from heat pump and integrate them to the passed dictionary.
This dictionary is returned afterwards, mainly for access to a newly created.
"""
if visibilities is None:
visibilities = Visibilities()
return self._with_lock_and_connect(self._read_visibilities, visibilities)

def write(self, parameters):
"""
Write all set parameters to the heat pump.
:param Parameters() parameters Parameter dictionary to be written
to the heatpump before reading all available data
from the heat pump.
"""
self._with_lock_and_connect(self._write, parameters)

def write_and_read(self, parameters, data=None):
"""
Write all set parameter to the heat pump (see write())
prior to reading back in all data from the heat pump (see read())
after a short wait time
"""
if data is None:
data = LuxtronikData()
return self._with_lock_and_connect(self._write_and_read, parameters, data)

def _read(self, data):
self._read_parameters(data.parameters)
self._read_calculations(data.calculations)
self._read_visibilities(data.visibilities)
return data

def _write_and_read(self, parameters, data):
self._write(parameters)
return self._read(data)

def _write(self, parameters):
for index, value in parameters.queue.items():
if not isinstance(index, int) or not isinstance(value, int):
LOGGER.warning(
"%s: Parameter id '%s' or value '%s' invalid!",
self._host,
index,
value,
)
continue
LOGGER.info("%s: Parameter '%d' set to '%s'", self._host, index, value)
self._send_ints(LUXTRONIK_PARAMETERS_WRITE, index, value)
cmd = self._read_int()
LOGGER.debug("%s: Command %s", self._host, cmd)
val = self._read_int()
LOGGER.debug("%s: Value %s", self._host, val)
# Flush queue after writing all values
parameters.queue = {}
# Give the heatpump a short time to handle the value changes/calculations:
time.sleep(WAIT_TIME_AFTER_PARAMETER_WRITE)

def _read_parameters(self, parameters):
data = []
self._send_ints(LUXTRONIK_PARAMETERS_READ, 0)
cmd = self._read_int()
LOGGER.debug("%s: Command %s", self._host, cmd)
length = self._read_int()
LOGGER.debug("%s: Length %s", self._host, length)
for _ in range(0, length):
data.append(self._read_int())
LOGGER.info("%s: Read %d parameters", self._host, length)
parameters.parse(data)
return parameters

def _read_calculations(self, calculations):
data = []
self._send_ints(LUXTRONIK_CALCULATIONS_READ, 0)
cmd = self._read_int()
LOGGER.debug("%s: Command %s", self._host, cmd)
stat = self._read_int()
LOGGER.debug("%s: Stat %s", self._host, stat)
length = self._read_int()
LOGGER.debug("%s: Length %s", self._host, length)
for _ in range(0, length):
data.append(self._read_int())
LOGGER.info("%s: Read %d calculations", self._host, length)
calculations.parse(data)
return calculations

def _read_visibilities(self, visibilities):
data = []
self._send_ints(LUXTRONIK_VISIBILITIES_READ, 0)
cmd = self._read_int()
LOGGER.debug("%s: Command %s", self._host, cmd)
length = self._read_int()
LOGGER.debug("%s: Length %s", self._host, length)
for _ in range(0, length):
data.append(self._read_char())
LOGGER.info("%s: Read %d visibilities", self._host, length)
visibilities.parse(data)
return visibilities

def _send_ints(self, *ints):
"Low-level helper to send a tuple of ints"
data = struct.pack(">" + "i" * len(ints), *ints)
LOGGER.debug("%s: sending %s", self._host, data)
self._socket.sendall(data)

def _read_bytes(self, count):
"Low-level helper to receive a precise number of bytes"
total_reading = b""

while len(total_reading) is not count:
missing = count - len(total_reading)

reading = self._socket.recv( missing )

if len(reading) == 0:
LOGGER.error("%s: Connection died.", self._host)
raise ConnectionError("Connection to %s died." % self._host)

total_reading += reading

if len(reading) is not missing:
LOGGER.debug("%s: received %s bytes out of %s bytes. Will read again.", self._host, len(reading), missing)

return total_reading

def _read_int(self):
"Low-level helper to receive an int"
reading = self._read_bytes(LUXTRONIK_SOCKET_READ_SIZE_INTEGER)
return struct.unpack(">i", reading)[0]

def _read_char(self):
"Low-level helper to receive a signed int"
reading = self._read_bytes(LUXTRONIK_SOCKET_READ_SIZE_CHAR)
return struct.unpack(">b", reading)[0]


class LuxtronikAllData(LuxtronikData, LuxtronikSmartHomeData):
"""
Expand Down
12 changes: 12 additions & 0 deletions luxtronik/cfi/__init__.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,12 @@
"""
Python module for controlling a Luxtronik heat pump controller
via the config interface.
"""

from luxtronik.cfi.constants import (
LUXTRONIK_DEFAULT_PORT, # noqa: F401
)
from luxtronik.cfi.calculations import CALCULATIONS_DEFINITIONS, Calculations # noqa: F401
from luxtronik.cfi.parameters import PARAMETERS_DEFINITIONS, Parameters # noqa: F401
from luxtronik.cfi.visibilities import VISIBILITIES_DEFINITIONS, Visibilities # noqa: F401
from luxtronik.cfi.interface import LuxtronikData, LuxtronikSocketInterface # noqa: F401
4 changes: 2 additions & 2 deletions luxtronik/calculations.py → luxtronik/cfi/calculations.py
100755 → 100644
Original file line number Diff line number Diff line change
Expand Up @@ -3,10 +3,10 @@
import logging
from typing import Final

from luxtronik.definitions import LuxtronikDefinitionsList
from luxtronik.definitions.calculations import CALCULATIONS_DEFINITIONS_LIST, CALCULATIONS_OFFSET

from luxtronik.constants import CALCULATIONS_FIELD_NAME
from luxtronik.shi.definitions import LuxtronikDefinitionsList
from luxtronik.cfi.constants import CALCULATIONS_FIELD_NAME
from luxtronik.data_vector import DataVector
from luxtronik.datatypes import Base

Expand Down
23 changes: 23 additions & 0 deletions luxtronik/cfi/constants.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,23 @@
"""Constants used throughout the Luxtronik config interface (CFI) module."""

# Default port to be used to connect to Luxtronik controller.
LUXTRONIK_DEFAULT_PORT = 8889

LUXTRONIK_PARAMETERS_WRITE = 3002
LUXTRONIK_PARAMETERS_READ = 3003
LUXTRONIK_CALCULATIONS_READ = 3004
LUXTRONIK_VISIBILITIES_READ = 3005

LUXTRONIK_SOCKET_READ_SIZE_PEEK = 16

LUXTRONIK_SOCKET_READ_SIZE_INTEGER = 4
LUXTRONIK_SOCKET_READ_SIZE_CHAR = 1

# Identifier of calculation data-vectors and partial name for unknown calculation fields
CALCULATIONS_FIELD_NAME = "calculation"

# Identifier of parameter data-vectors and partial name for unknown parameter fields
PARAMETERS_FIELD_NAME = "parameter"

# Identifier of visibilities data-vectors and partial name for unknown visibility fields
VISIBILITIES_FIELD_NAME = "visibility"
Loading