- The message box of the main page had a fixed height and always showed the title and 4 lines, empty ones included: send only the lines in use and let the box fit (and wrap) its content. - The LORAtoMQTT display only handled tempc/hum/adc (and wrote the adc line over the humidity one): every other LoRa message (hex packets, text, decoded devices, the gateway LoRa configuration) showed only its title. Show the sender (name or id, model), its data fields, and the radio information (rssi, snr, fcnt), or the radio settings for the configuration message. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
1technophile
left a comment
There was a problem hiding this comment.
Tested this revision on a connected M5Stack Core (ESP32, 4 MiB flash). The standard PR firmware built, booted, connected to Wi-Fi, and served the authenticated home, message, and information pages successfully. Automatic message-box height and wrapping worked.
For the LoRa display checks, a temporary test adapter enabled the unchanged LoRa formatter without a radio and injected sample messages on the physical ESP32. The real HTTP responses were checked, along with browser rendering. This validates formatting, not LoRa RF reception; MQTT and live BLE reception were not validated.
10 of 13 formatting checks passed, including empty-row removal, LoRa configuration display, temperature conversion, humidity plus ADC, short hex, and escaped message text. The three failing cases identify two issues that should be fixed before merging: unescaped sender fields allow HTML injection, and an oversized data field suppresses itself and subsequent fields. Details and reproductions are inline.
Please escape all sender fields and handle oversized values without abandoning the remaining fields, then rerun these cases.
| } else { | ||
| // Line 1: the sender | ||
| if (data.containsKey("name")) { | ||
| line1 = data["name"].as<String>(); |
There was a problem hiding this comment.
[P1] Escape sender fields before inserting them into the WebUI HTML. The new name/id/model values are copied into line1 without the escaping applied to data items below. On the physical ESP32, injecting {"name":"sensor","tempc":20,"rssi":-60,"snr":9} returned the literal sensor in /?m=1, and the browser interpreted it as markup. Since the page inserts this response using innerHTML, untrusted sender fields create an HTML-injection path. Escape name, id, and model before rendering them, and add coverage showing that HTML-like sender values remain literal text.
| } | ||
| item.replace("<", "<"); | ||
| String& line = line2.length() + item.length() + 2 < WEBUI_TEXT_WIDTH ? line2 : line3; | ||
| if (line.length() + item.length() + 2 >= WEBUI_TEXT_WIDTH) break; |
There was a problem hiding this comment.
[P2] Do not abandon all remaining fields when one value exceeds the line buffer. This break exits the entire JSON-field loop. On the physical ESP32, an 80-byte hex packet ("AB" repeated 80 times) displayed only the title and radio metadata, with no payload. A message of 140 characters followed by tempc and hum also hid both sensor fields. Please truncate or split oversized values with a visible indication, or at least skip only that field and continue processing subsequent fields. Cover both a long hex payload and an oversized first field followed by short sensor values.
Description:
The message box of the main WebUI page had two problems.
Layout. The box had a fixed height (
height:7.5em,white-space: pre), and the live message (/?m=1) always contained the title plus 4 lines, empty ones included. The box therefore showed blank rows and didn't fit its content. Now only the lines in use are sent, and the box fits and wraps its content (white-space: pre-wrap, no fixed height). This applies to every module.LoRa messages. The
LORAtoMQTTcase only handledtempc,humandadc, and wrote theadcline intoline2, overwriting the humidity. Every other LoRa message (hex packets, text, decoded devices, the gateway LoRa configuration message) showed only its title. It now shows:nameorid, with themodel)rssi,snr,fcnt)Built
ttgo-lora32-v21andesp32dev-all-testwith no warnings. Tested on a LilyGo LoRa32 V2.1:Checklist: