Describe the bug
In Freeze Charge the battery oscillates between charging at zero and ~3,000W. This is as monitored with a CT clamp on the inverter rather than from the inverter stats.
Between midnight and 5am you can clearly see the on/off oscaillations of the battery charging.

At the same time the inverter is supporting the house load correctly and doesn't show the same oscillation.

House load for context:
The Solis Cloud configuration also seems to have an incorrect charge/discharge rate much higher than the inverter's 3kW rating, maybe this is a separate issue. I have attempted to override these settings to actual capability with:
inverter_limit_charge: 3300
Expected behaviour
I would expect Freeze Charge to hold the battery state and not discharge. Should I just disable freeze charging in the plan as this inverter does not seem to support it properly?
Predbat version
v8.34.2
Environment details
- Inverter and battery setup
Solis S5-EH1P5K-L - No solar attached, 4x pylontech US3000C
There is Solar on Enphase micro-inverters separate from this inverter. - Standard HAOS installer or Docker
HAOS - Anything else?
Control with Solis Cloud
Screenshots
If applicable, add screenshots to help explain your problem. The most useful ones can be your battery chart, the Predbat HTML plan and your current settings in HA.
Log file
Attached
Predbat debug yaml file
Does not appear to be plan related