Overview
Collect community feedback and testing results for Synaccess netCommander/netBooter devices beyond the tested NP-0501DU model to expand compatibility documentation.
Tested Device
✅ Synaccess netBooter™ Model: NP-0501DU (5-outlet model)
- Fully tested and working
- All features confirmed: outlet control, monitoring, reboot
- Physical outlet mapping documented
Help Expand Compatibility!
We need community testing to verify compatibility with other Synaccess models:
Potentially Compatible Models
- Other netBooter™ series: NP-0501, NP-0201, NP-0801, etc.
- netCommander series devices
- Different outlet counts: 2, 4, 6, 8+ outlet models
- Different firmware versions
How to Test
- Install integration via HACS (as custom repository for now)
- Configure with your device IP and credentials
- Test thoroughly:
- ✅ Device detection and setup
- ✅ Outlet control (on/off/reboot)
- ✅ Status monitoring (current, temperature)
- ✅ Physical outlet mapping verification
- Report results in this issue
What to Report
Please provide:
Device Information
- Model number (e.g., "NP-0501DU")
- Outlet count (e.g., "5 outlets")
- Firmware version (if accessible)
- Device age/purchase date (approximate)
Test Results
- ✅ Working / ❌ Not Working / ⚠️ Partial
- Outlet mapping: Which HA entity controls which physical outlet
- Any error messages or issues encountered
- Special configuration needed (if any)
Example Report
**Model**: NP-0801DU
**Outlets**: 8
**Firmware**: v2.1.3
**Status**: ✅ Working
**Mapping**: Standard (HA 1→Physical 1, etc.)
**Notes**: All features work perfectly, no issues
Integration Features to Test
- Outlet Control: Turn outlets on/off via HA switches
- Outlet Reboot: Power cycle outlets via HA buttons
- Current Monitoring: Total current sensor readings
- Temperature Monitoring: Device temperature sensor
- Entity Grouping: All entities grouped under device
- State Synchronization: UI updates after commands
Important Notes
⚠️ Physical outlet mapping may vary between models - please test which HA entity controls which physical outlet!
🔧 Device Configuration: Ensure "Lock Web Outlet ON/OFF And Reboot Operation" is unchecked in device settings.
Community Benefits
Your testing helps:
- 📖 Improve documentation with verified compatible models
- 🐛 Identify issues specific to certain models
- 🔧 Guide fixes for model-specific quirks
- 👥 Help other users with same devices
Integration Repository: https://github.com/rmrfslashbin/netcommander
Installation Guide: See README.md
Current Version: v2.1.1
Overview
Collect community feedback and testing results for Synaccess netCommander/netBooter devices beyond the tested NP-0501DU model to expand compatibility documentation.
Tested Device
✅ Synaccess netBooter™ Model: NP-0501DU (5-outlet model)
Help Expand Compatibility!
We need community testing to verify compatibility with other Synaccess models:
Potentially Compatible Models
How to Test
What to Report
Please provide:
Device Information
Test Results
Example Report
Integration Features to Test
Important Notes
🔧 Device Configuration: Ensure "Lock Web Outlet ON/OFF And Reboot Operation" is unchecked in device settings.
Community Benefits
Your testing helps:
Integration Repository: https://github.com/rmrfslashbin/netcommander
Installation Guide: See README.md
Current Version: v2.1.1