At this point we have several cases that we effective take offline by using a "0" instead of a "Rate of Spread" quantity for USFS Catchpole. There are two issues:
&DEVC ID='xT', QUANTITY='TEMPERATURE', SPATIAL_STATISTIC='MAXLOC X', XB=0,8,-0.1,0.1,0,0.203 /
&DEVC ID='x',QUANTITY='CONTROL VALUE',CTRL_ID='x proc'/
&DEVC ID='flag val',QUANTITY='CONTROL',CTRL_ID='flag'/
&DEVC ID='t', XYZ=0,0,0, QUANTITY='TIME', OUTPUT=F, SETPOINT=11.0/
&DEVC ID='HRR', QUANTITY='HRRPUV', XB=-1.,9.,-1.5,1.5,0.,3., SPATIAL_STATISTIC='VOLUME INTEGRAL',
OUTPUT=F, SETPOINT=0.1, LATCH=F, TRIP_DIRECTION=-1/
&CTRL ID='flag', FUNCTION_TYPE='ALL', INPUT_ID='t','HRR',INITIAL_STATE=T/
&CTRL ID='x proc',FUNCTION_TYPE='MULTIPLY',INPUT_ID='xT','flag val'/
Eric, I leave it up to you how you want to proceed. If you want help changing the slope logic let me know.
At this point we have several cases that we effective take offline by using a "0" instead of a "Rate of Spread" quantity for USFS Catchpole. There are two issues:
I tested Jason's new CTRL logic and fixed a couple of minor things:
Eric, I leave it up to you how you want to proceed. If you want help changing the slope logic let me know.