diff --git a/paper/manuscript.md b/paper/manuscript.md index 36b588f6ab..30db44ecb9 100644 --- a/paper/manuscript.md +++ b/paper/manuscript.md @@ -392,51 +392,43 @@ Manual-reference accuracy remains unmeasured: the detector totals are not validated retinal cell counts (Supplementary Data 8). -Whole-volume trials combined annotated-centre localisation with native -instance review. An early fresh nucleus-centre trial matched all 15 manual reference -centres within 30 voxels, with ten unmatched predictions; at ten voxels it -matched 14 of 15. The reference was not established as exhaustive, so unmatched -centres were not automatically treated as spurious cells. Its bright-core -adjustment left first and final geometries unchanged. Another fresh author measured nuclear dimensions, background intensity -and neighbour separation before selecting a shape-based marker method. Its -first scientific method produced 26 candidate centres; a technical rerun -changed output delivery while retaining the same detector. Independent raw, -point-only and combined XY/XZ/YZ review supported centre placement inside -ordinary nuclei. A bright lobed complex and cropped border supports retained -identity uncertainty. After the workflow was frozen, one-to-one matching recovered -all 15 manually annotated centres within the predeclared 30-voxel distance, -with a mean localisation error of 4.80 voxels (Figure 9). All 15 also matched within -20 voxels, and 14 matched within 10 voxels. Eleven of the 26 predictions were -unmatched to these annotations. Their coverage was not established as -exhaustive, so unmatched predictions do not establish false biological -detections. - -A subsequent independent volume author repaired internal-peak duplication -while retaining separate neighbours (Supplementary Figure 25). Post-freeze matching again recovered all -15 annotated centres within 20 and 30 voxels, and 14 within 10 voxels; mean -localisation error at 30 voxels was 4.82. Its 26 candidates included 16 -border-touching basins and 11 predictions unmatched to the incomplete reference. -This repeats annotated-centre localisation rather than improving it or -establishing a complete nucleus census. Separate fresh trials retained 26 and -22 provisional centres after repairing sampled internal-peak duplicates; -native XY, XZ and YZ views supported ordinary-body placement and retained -neighbour controls, while bright multi-lobed complexes and border supports -remained uncertain (Supplementary Figure 17). These unscaled voxel distances -assess centre placement, not physical distance or segmentation boundaries. -Supplementary Data 8 preserves the distinct trials, local repairs and -remaining whole-volume uncertainties. - -A further independent volume author reduced 31 first-attempt centres to 26 -after diagnosing duplicated markers on connected distance plateaus and -associating nearby seeds within admitted components. Matched native XY, XZ -and YZ review supported repaired ordinary-body placement while retaining a -clear pair and a dim nucleus. A fragmented bright group and cropped objects -remained uncertain. This is self-directed repair without reference feedback; -the reduced count alone does not establish an exhaustive nucleus census -(Supplementary Data 8). Independent post-freeze matching recovered all 15 -annotated centres within 20 and 30 voxels in both candidates; mean localization -error decreased from 5.37 to 4.86 voxels. Unmatched predictions decreased from -16 to 11, but the incomplete reference does not establish these as false cells. +Whole-volume trials tested whether agents could locate nuclei and repair +duplicate detections without reference feedback. One fresh author measured +nuclear dimensions, background intensity and neighbour separation before +choosing shape-based markers. Its first scientific method produced 26 centres; +a technical rerun changed output delivery without changing the detector. +Matched raw, point-only and combined XY/XZ/YZ views supported placement inside +ordinary nuclei. After freezing, one-to-one matching recovered all 15 manual +reference centres within the predeclared 30-voxel distance, with a mean +localisation error of 4.80 voxels (Figure 9). All 15 also matched within +20 voxels, and 14 within 10 voxels. Eleven predictions were unmatched. The +annotations were not established as exhaustive, so unmatched predictions do +not establish false biological detections. Distances are in unscaled voxels +and assess centre placement rather than physical distance or mask boundaries. + +Independent repeats supported similar localisation with variable instance +separation. An early trial matched 15 centres within 30 voxels and 14 within +10 voxels, with ten unmatched predictions; its bright-core adjustment left +first and final geometries unchanged. Another author repaired internal-peak +duplication while retaining neighbours (Supplementary Figure 25). Its 26 +candidates included 16 border-touching basins and 11 unmatched predictions; +all 15 reference centres matched within 20 and 30 voxels, and 14 within +10 voxels, with a mean error of 4.82 voxels at 30 voxels. Two further trials +retained 26 and 22 provisional centres after local duplicate repairs +(Supplementary Figure 17). Native views supported ordinary-body placement, +while bright lobed complexes and cropped objects retained uncertain identity. + +A later author improved its own result after diagnosing duplicated markers +on connected distance plateaus. Associating nearby seeds within admitted +components reduced 31 first-attempt centres to 26. Matched XY/XZ/YZ review +supported repaired placement while retaining a clear pair and a dim nucleus; +a fragmented bright group and cropped objects remained uncertain. +Post-freeze matching recovered all 15 annotated centres within 20 and +30 voxels in both candidates. Mean localisation error decreased from +5.37 to 4.86 voxels, and unmatched predictions decreased from 16 to 11. +The paired comparison demonstrates self-directed localisation repair; +complete nucleus counts remain unvalidated. Supplementary Data 8 retains +the distinct trials, first/final comparisons and remaining uncertainties. A fresh public neurite-field author identified bright junction pixels lost after ridge enhancement and restored them by combining enhanced support with