Local web interface

opendiag serve <same connection options as scan> connects to the module, then serves a page on 127.0.0.1 (this computer only). The first line printed is the URL to open; it contains a random token that changes every run. Stop with Ctrl-C (the session is closed on exit).

It is read-only: identification, fault codes (with descriptions from the open data files when present) and raw live data. Clearing codes and adaptation changes are not offered, because they must go through the guarded backup-and-confirm flow in the command line (see safety.md).

Why it is built this way

The server is attached to a vehicle's diagnostic port, so a web page you happen to visit must not be able to read from it. Every request goes through one pure function (opendiag-web), which enforces:

  • Host check: only 127.0.0.1:<port> and localhost:<port>. Defeats DNS rebinding.
  • Token: required in an X-OpenDiag-Token header for /api/* (and as ?t= for the first page load). A foreign page cannot send a custom header without a CORS preflight, and none is ever answered.
  • GET only, no endpoint that changes anything.
  • Strict CSP (no inline script, no external origins), nosniff, no-store, no referrer. The page code puts module text into the page with textContent only; a test bans innerHTML and friends.

Requests are handled one at a time, so the diagnostic session is never used concurrently. When idle, the server sends keep-alive messages; if one fails, the API answers 503 until you restart.

Live data view

Each measuring-block cell gets its own tile: the latest raw value (A×256+B), its min and max over the visible window, and a sparkline on its own scale. Controls: start/pause, clear, sample interval (0.5 to 5 s), and a CSV download of everything read this session (time_ms,group,cell,formula,a,b, the same columns as opendiag log). Under --replay the page says so and plays the recording back (replay.md).

Limits

  • Live data is KW1281 only, as raw cells (formula, A, B). Values are not converted to units, and the chart plots A×256+B.
  • Anyone who can run programs as you on this computer can read the token from the process or the URL. It is not a defence against local malware.
  • Simulator-tested only; see status.md.