// vertical_pipe_check.js
// Check if vertical pipe can sustain the required flow (Wyly–Eaton equation approximation)
const input = require('./inputData');
const { calculateRequiredOWSFlowRate } = require('./OWS_size_calc');
/**
* Calculates maximum flow rate through a vertical pipe using Wyly–Eaton approximation
* @param {number} diameter - pipe internal diameter (m)
* @param {number} height - vertical height (m)
* @param {number} fillingDegreeVer - assumed pipe filling (0 < x <= 1)
* @returns {number} maxFlowLps - max flow rate in liters per second (L/s)
*/
function calculateVerticalPipeCapacity(diameter, height, fillingDegreeVer) {
const g = 9.81;
// Cross-sectional area (m²)
const area = Math.PI * Math.pow(diameter, 2) / 4 * fillingDegreeVer;
// Simplified vertical discharge velocity: v = sqrt(2gh)
const velocity = Math.sqrt(2 * g * height);
const flowRate = area * velocity; // m³/s
return flowRate * 1000; // L/s
}
module.exports = {
calculateVerticalPipeCapacity,
testVerticalPipe: () => {
const totalRequiredFlow = calculateRequiredOWSFlowRate();
const flowPerBranch = totalRequiredFlow / input.pipeBranchCount;
const branchCapacity = calculateVerticalPipeCapacity(
input.pipeDiameterM,
input.verticalHeightM,
input.fillingDegreeVer
);
const totalCapacity = branchCapacity * input.pipeBranchCount;
return {
flowPerBranch: flowPerBranch.toFixed(3),
branchCapacity: branchCapacity.toFixed(3),
totalCapacity: totalCapacity.toFixed(3),
isSufficient: totalCapacity >= totalRequiredFlow,
};
}
};