FastACL Hardware Lab

The lab runs the HW suites of docs/test-strategy.md (L5–L7). This page describes the machines, the cabling, and how CI reaches the lab. Host names, BMC and PDU addresses, credentials and MAC addresses are not in this repository: they come from the LAB_ENV secret, rendered into labs/hw/lab.env at run time (see labs/hw/lab.env.example for the variables).

Machines

Name Role CPU NIC Profile
server1 DUT, 2n-rome-cx7; since 2026-10-09 the six-port TG for 2n-platform AMD EPYC 7742 (Rome), 64 cores / 128 threads was: ConnectX-7, dual port, links at 200 Gbps. Now: 2× ConnectX-7 (81:00, c2:00, 200G) and 3× ConnectX-5 Ex (01:00, 82:00, c1:00, 100G) labs/hw/profiles/server1.env, GEN=server1
epyc-sp5 DUT, 2n-genoa-bf3 AMD EPYC 9534 (Genoa), 64 cores, PCIe Gen5 BlueField-3 B3240 (integrated ConnectX-7), host NIC mode labs/hw/profiles/epyc-sp5.env
epyc-sp5 DUT, 2n-genoa-cx8 (since 2026-10-07; BlueField-3 removed) AMD EPYC 9534 (Genoa), 64 cores, 12× DDR5-4800 alice's ConnectX-8 in CPU SLOT5, links at 400 Gbps; PCIe Gen5 x16 labs/hw/profiles/epyc-cx8.env, TG bob
epyc-sp5 DUT, 2n-platform (since 2026-10-09) AMD EPYC 9534 (Genoa), 64 cores, 12× DDR5-4800 alice's ConnectX-8 (41:00, CPU SLOT5), bob's ConnectX-8 (0a:00) and the BlueField-3 back in NIC mode (03:00); six ports, all ingress labs/hw/profiles/epyc-platform.env, TG server1
bluefield3 DUT, 2n-bf3-arm BlueField-3 Arm, 16× Cortex-A78 the same BlueField-3 in DPU mode labs/hw/dpu/
alice DUT (profile alice) and TG for bob; no NIC since 2026-10-07 (card moved to epyc-sp5) AMD Ryzen 9 9950X, 16 cores / 32 threads ConnectX-8, dual port, links at 400 Gbps; PCIe Gen5 x16 (half of the card's Gen6 x16) labs/hw/profiles/alice.env, GEN=alice
bob DUT (profile bob) and TG for alice AMD Ryzen 9 9950X, 16 cores / 32 threads ConnectX-8, dual port, links at 400 Gbps; PCIe Gen5 x16 labs/hw/profiles/bob.env, GEN=bob
flame1 TG for server1 AMD Ryzen 7 5800X ConnectX-7, dual port GEN=flame
lava1 TG for epyc-sp5 and bluefield3 AMD Ryzen 9 9950X 2× ConnectX-5 Ex (one sender card, one receiver card) GEN=lava
dell spare TG 2× Intel Xeon Gold 6230R 2× ConnectX-5 GEN=dell
rackpi out-of-band proxy Raspberry Pi 5 — reaches the BMCs and PDUs

The BMCs (IPMI, iDRAC) and two networked PDUs sit on the lab's management LAN and are reached only through rackpi. labs/hw/bringup-guarded.sh uses them to recover a DUT whose NIC wedged during DPDK initialisation: first an IPMI power cycle, then a PDU power drain.

alice and bob have no BMC; each has a JetKVM on the same management LAN instead, driven by labs/hw/setup/kvm.sh <host> {status|reboot|sysrq-reboot|on|off|cycle|reset} (and by setup/ipmi.sh --target dut for those profiles). reboot (Ctrl+Alt+Del) and sysrq-reboot type on the host's keyboard, so they need a live kernel. Power on/off/cycle/reset press the motherboard buttons and need the JetKVM ATX extension, which is not fitted yet. Every call takes over the KVM session, signing out anyone using its web UI.

alice and bob host changes

Reports from alice and bob before and after these dates were taken on differently configured hosts. Every report since f15f13f names the DUT's memory speed in its header (DUT memory).

Change Since Where Effect
iommu=pt on the kernel command line 2026-10-03 setup/install.sh TRex rate unchanged (300 Mpps per CX-8 is the card's packet rate); VPP starts in ~72 s instead of ~170 s
ASPM L1 off on the Intel I226 management port 2026-10-05 setup/install.sh (udev rule) stops the port dropping off PCIe ("PCIe link lost") under heavy transfers
DDR5-6000 via EXPO, both hosts 2026-10-05 BIOS by hand: Ai Tweaker → Ai Overclock Tuner = EXPO II memory was running at 4800; see below. Not scripted: a BIOS update or CMOS clear reverts it
Firmware reset repeated when the CX-8 PCIe link trains below the slot speed 2026-10-05 setup/mellanox-init.sh bob's card came back at 2.5 GT/s on 2 of 8 resets and then ran at ~22 Mpps

The EXPO profiles differ slightly: alice's modules (KF560C36-16) load DDR5-6000 36-44-44-90, bob's (KF560C36BBE2-16TR) DDR5-6000 38-48-48-96, both at 1.35 V. Each host passed a 5-minute stress-ng --vm --verify run at 6000 before any measurement.

Enabling EXPO remotely

Run it with the host idle (no DUT or TRex containers). Watch every step with labs/hw/setup/kvm.sh <host> screenshot <file.png>; keys go through the JetKVM keyboard.

  1. On the host: sudo systemctl reboot --firmware-setup. The board boots straight into UEFI setup, so no key has to be timed during POST.
  2. Wait until a screenshot shows the setup screen (EZ Mode), about 80 s. Keys sent earlier are lost or land on the wrong screen.
  3. Press F7 for Advanced Mode, then Right to the Ai Tweaker tab.
  4. On Ai Overclock Tuner press Enter, choose EXPO II (three entries below Auto) and press Enter. The EXPO line under it must show the module's profile (DDR5-6000 …, 1.35 V) and Target DRAM Frequency 6000 MHz.
  5. Press F10. The Save Changes & Reset dialog must list only Ai Overclock Tuner, Memory Frequency and the memory timings; if anything else is there, choose Cancel and reset without saving (Ctrl+Alt+Del). Otherwise confirm Ok.
  6. The first boot at the new speed trains the memory (60–110 s here). Then check sudo dmidecode -t memory shows Configured Memory Speed: 6000 MT/s and run stress-ng --vm 32 --vm-bytes 70% --vm-method all --verify --timeout 300s with no failures and no machine-check errors in dmesg.

To revert, repeat with Ai Overclock Tuner = Auto.

Same day, same software, CALIBRATE runs of the gate and ceiling stages, DUT absorbed Mpps:

Test (64 B unless noted) alice 4800 alice 6000 bob 4800 bob 6000
5rules-drop 185.4 198.6 187.4 198.9
country-set-drop 186.3 199.8 186.3 199.2
1m-rules-drop, cold-scan 184.4 199.7 185.2 200.0
1m-rules-drop, cold-scan-imix 85.1 102.7 85.9 97.5
1m-rules-drop-ip6 184.5 200.0 185.0 200.1
ceiling, 3/3 rules 183.8 199.8 187.9 200.1
report 1307 1335 1416 1526

At 6000 the 64 B scenarios absorb the full 200 Mpps the suite offers. Offered more by a single stream (5 drop rules, every processed packet confirmed dropped), alice drops ~196 Mpps at 250 and 300 Mpps offered (157 at 4800) and 187 Mpps with 150 + 150 on two ports (149 at 4800). The cost of the filter node is unchanged (~76–79 cycles/packet); the receive node dpdk-input falls from ~206 to ~150 cycles/packet, so at 4800 the hosts were memory-bound, not CPU-bound.

DRAM traffic stays at ~340–350 bytes per 64 B packet at both speeds (perf stat on the amd_umc_0/1 PMUs, event 0xa, rdwrmask=1 reads / 2 writes, 64 B per count; needs modprobe amd_uncore). AMD SDCI (cache injection) would cut that but is not usable on these boards: the CPU reports SDCIAE in CPUID, but the BIOS has no TPH/SDCI option and the ACPI tables no steering-tag _DSM, and enabling the CX-8's TPH requester changed nothing measurable.

Cabling

flame1  sender   ──100G──►  server1 eth-left   (ingress)
flame1  receiver ◄─100G───  server1 eth-right  (egress)

lava1   card B   ──100G──►  epyc-sp5 BF-3 port 1  (ingress)
lava1   card A   ◄─100G───  epyc-sp5 BF-3 port 0  (egress)

bob   port 1  ──400G──►  alice port 1  (ingress)      alice port 1 ──400G──►  bob port 1  (ingress)
bob   port 0  ◄─400G───  alice port 0  (egress)       alice port 0 ◄─400G───  bob port 0  (egress)

bob   port 1  ──400G──►  epyc-sp5 CX-8 port 1  (ingress)
bob   port 0  ◄─400G───  epyc-sp5 CX-8 port 0  (egress)

Since 2026-10-09 (2n-platform, every epyc-sp5 port is an ingress; TRex port number first):

server1 0  CX-7 #1   81:00.1  ──200G──►  epyc-sp5 CX-8 A port 1  41:00.1
server1 1  CX-7 #2   c2:00.0  ──200G──►  epyc-sp5 CX-8 B port 1  0a:00.1
server1 2  CX-5 #1   01:00.1  ──100G──►  epyc-sp5 CX-8 B port 0  0a:00.0
server1 3  CX-5 #1   01:00.0  ──100G──►  epyc-sp5 CX-8 A port 0  41:00.0   (autonegotiation off on both ends)
server1 4  CX-5 #2   82:00.0  ──100G──►  epyc-sp5 BF-3 port 0    03:00.0
server1 5  CX-5 #3   c1:00.0  ──100G──►  epyc-sp5 BF-3 port 1    03:00.1

The ConnectX-7 to ConnectX-8 links run at 200G on 400G DACs. The 01:00.0–41:00.0 DAC links only at a forced 100G with autonegotiation off on both ends; GEN_FORCE_100G and SINK_FORCE_100G in vars.sh make perf-tune.sh do that. Run it with labs/hw/run.sh epyc-platform platform (labs/hw/platform-ceiling.sh): stages add generator cards one group at a time, small frames only. TRex takes at most 48 data-plane cores, 16 per port pair. VPP runs 62 workers there, one receive queue each, with 524,288 buffers per NUMA node, and needs the BIOS at NPS4 (below).

Tuning epyc-sp5 for the platform ceiling (2026-10-09)

All six ports loaded, 64 B, VPP dropping everything; one trial unless noted:

Host setting 16 w 24 w 32 w 48 w 62 w
NPS1 (one NUMA node), IOMMU translated 212 296 346–355 191 148
NPS1, iommu=pt 328 150
NPS1, 1024-entry receive rings 135
NPS4, iommu=pt 329–336 363 420–464 (6 trials; full report 2026-10-09_1331: 450)
NPS4 + L3 cache as NUMA domain (8 nodes) 332 389 356–403 (3 trials)
NPS4, mlx5 Multi-Packet RQ (mprq_en=1) 401

Why: VPP keeps one packet-buffer pool per NUMA node. Every receive-ring refill (dpdk_ops_vpp_dequeue, src/plugins/dpdk/buffer.c) and every freed packet go through a 512-buffer per-thread cache and, when it runs empty or full, through the shared pool under one spinlock (vlib_buffer_pool_get/put, src/vlib/buffer_funcs.h). At NPS1 all 62 workers, on eight CPU dies, share that lock: dpdk_ops_vpp_dequeue takes 55 % of a worker, error_drop 20 %, the filter 5 %, and show runtime shows 937 cycles per packet (dpdk-input 636, drop 193, filter 82). At NPS4 a receive queue takes its buffers from the pool of the NIC's node (src/plugins/dpdk/device/common.c): ConnectX-8 A is on node 2 (24 workers), ConnectX-8 B and the BlueField-3 on node 3 (38 workers), and each pool's memory sits in that quadrant. The same 62 workers then spend 291 cycles per packet (dpdk-input 105, drop 17, filter 102) and allocation is 9 % of a worker. iommu=pt and Multi-Packet RQ change nothing measurable; L3-as-NUMA is worse than NPS4 alone.

Buffer-path experiments at NPS4 (2026-10-09)

62 workers, all six ports, median of 3 trials; the generator offered ~750-800 Mpps in this session (below the ~890 of the published runs), so compare rows within a block, not with the report.

Change Mpps dropped vs. baseline
ACL plugin loaded — default queue placement (port order) 387
NIC-local placement: ConnectX-8 A port 1 on node 2 cores, ConnectX-8 B port 1 on node 3 cores (SINK_ORDER, SINK_CORELIST) 408 +5 %; NIC discards 19 → 3 Mpps
VPP rdma driver instead of DPDK (after the MAC fix below) 336 −15 %; buffer allocation gone from the profile, but vlib_buffer_enqueue_to_next 19 %, 10.7 packets per poll on average, 59 Mpps lost at the NIC
No ACL plugin — stock VPP 25.10 414
patched VPP, stock defaults 425 same as stock within noise
patched VPP, buffers { per-thread-cache 4096 } 459 +8–11 %
patched VPP, buffers { pools-per-numa 4 } (receive queue j uses pool j mod 4 of its NIC's node) 434 +2–5 %, within noise
both 456 no gain over the cache alone

The patch is labs/hw/patches/vpp-25.10-buffer-cache-pools.patch (against the VPP tree of the release bundle; build with FastACL's scripts/build-vpp-debs.sh). It makes the per-thread buffer cache size (stock: 512, compile time) and the number of pools per NUMA node runtime options. The ACL plugin is built against stock VPP's buffer structures and must not be loaded into the patched VPP, hence SINK_ACL=0 for those rows (DUT_IMAGE=vpp-dut:patched, extra buffers options through SINK_BUFFERS_EXTRA). It is an experiment, not part of any release.

The rdma driver's interfaces start with a random MAC and only steer frames sent to it; the sink now sets each to its port's MAC (set interface mac address). Before that fix every packet went to the kernel and VPP received nothing.

The BIOS options are Advanced > ACPI Settings > NUMA Nodes Per Socket and ACPI SRAT L3 Cache As NUMA Domain. Redfish refuses BIOS settings on this BMC (no DCMS licence), so labs/hw/setup/bios-numa.py --nps 4 sets them through the BMC's HTML5 KVM (Playwright through a SOCKS tunnel to the lab proxy), reboots and checks numactl -H. run.sh epyc-platform platform runs it by itself when the host's node count differs from SINK_NUMA_NODES (the machine running run.sh needs Python Playwright with Chromium for that), the sink warns about a mismatch, and every platform report shows the node count.

On 2026-10-09 alice, bob, flame1 and lava1 were offline: bob's ConnectX-8 is in epyc-sp5, so only epyc-platform runs.

alice and bob are cabled port to port, so either is the DUT and the other its generator: profile alice puts the DUT on alice, profile bob on bob. TRex releases up to v3.06 do not know the ConnectX-8, so their generator image is built once from TRex source (docker/Dockerfile.trex-src, pinned commit, DPDK 25.07) and kept as a private package, ghcr.io/garyachy/fastacl-testbench-trex. labs/hw/gen-image.sh pulls it on the machine running the bench (with GHCR_TOKEN or the gh login, through a throw-away docker config) and streams it to the generator with docker save | docker load, so no registry credential is stored on a lab host. VPP runs 15 workers on cores 1-15; the hosts have no BMC.

Since 2026-10-07 alice's ConnectX-8 sits in epyc-sp5 (CPU SLOT5) and the BlueField-3 is out of the box, so only epyc-cx8 (DUT epyc-sp5, generator bob) runs; epyc-sp5, bluefield3, alice and bob need their cards back first.

Two separate generator cards on lava1 avoid the receive ceiling of a single dual-port adapter. The BlueField-3 is owned by the host (NIC mode) for 2n-genoa-bf3 and by its Arm cores (DPU mode) for 2n-bf3-arm. Switching mode needs a cold power cycle; labs/hw/bf-mode.sh nic|dpu does it unattended (mlxconfig on the Arm, IPMI cycle of epyc-sp5, verify), and the suite scripts call it so each run finds the card in the mode it needs.

epyc-sp5 host changes

Change Since Where Effect
BlueField-3 removed, alice's ConnectX-8 fitted in CPU SLOT5 (41:00.0/.1), cabled port to port with bob 2026-10-07 by hand new rig epyc-cx8; card links at PCIe Gen5 x16 (the card is Gen6)
bob's ConnectX-8 added (0a:00.0/.1), BlueField-3 refitted (03:00), all cabled to server1 2026-10-09 by hand new rig epyc-platform
iommu=pt added to the kernel command line (backup grub.bak-20261009) 2026-10-09 /etc/default/grub no throughput change; matches the other hosts
BIOS NUMA Nodes Per Socket: Auto (NPS1) → NPS4 2026-10-09 setup/bios-numa.py VPP drops 450 Mpps instead of 148 with 62 workers (see tuning above)
isolcpus, nohz_full, rcu_nocbs widened from 1-32 to 1-63 2026-10-07 /etc/default/grub by hand (backup grub.bak-20261007) lets VPP run up to 62 workers; VPP refuses 63 (VPP_MAX_WORKERS 64 counts the main thread)

Run VPP with 32 workers on this rig (the epyc-cx8 default). Every worker owns one receive queue, and the ConnectX-8 loses packets at the port once more than 32 queues are active, as the ConnectX-7 does. A sweep on 2026-10-07 (32 / 48 / 62 workers, 300 Mpps offered) showed:

Scenario 32 48 62
5 rules, 64 B, one flow set 298 200 —
country-rules-drop 235 294 207
1M rules, mix-udptcp 219 269 240
1M rules, 983K active flows 163 250 267

48 or 62 workers only help the scenarios whose per-packet cost is high (hundreds of cycles); every light one loses 25-35 % in the NIC instead. Raise DUT_POLL_WORKERS only to study those.

Until 2026-10-09 epyc-sp5 booted without iommu=pt (IOMMU in translated mode, lazy flush). It has no MFT on the host, so mellanox-init runs inside the DUT image, which therefore carries pciutils for mlxfwreset. Its MACs are LAB_MAC_LEFT_epyc_cx8 / LAB_MAC_RIGHT_epyc_cx8 in lab.env.

Access from CI

Workflows run on GitHub-hosted runners and reach the lab over a Tailscale tailnet:

Secret Contents
TS_AUTHKEY Tailscale auth key (reusable, ephemeral, untagged) that joins the runner as a device of the user the lab hosts are shared with
LAB_SSH_KEY private key authorised on the lab hosts
LAB_ENV the full labs/hw/lab.env: host names, SSH user, BMC and PDU credentials, MACs
FASTACL_RELEASE_TOKEN read-only token for downloading FastACL release bundles
FASTACL_LAB_LICENSE_JSON, FASTACL_LAB_LICENSE_SIG a FastACL licence bound to the lab DUTs (optional; otherwise the bundle's evaluation licence)

All HW workflows share the hw-lab concurrency group, so only one run uses the lab at a time. Every run syncs this repository and the bundle to the hosts, builds the DUT image from the bundle, runs the suite, publishes the report, and tears the hosts back down: containers, images and the synced checkout are removed.

Running by hand

From a machine on the tailnet with a filled-in labs/hw/lab.env:

export DUT=server1 GEN=flame HOST_REPO=fastacl-testbench
rsync -az ./ "$LAB_SSH_USER@<dut>:~/fastacl-testbench/"       # and to the generator
ssh "$LAB_SSH_USER@<dut>" 'bash ~/fastacl-testbench/labs/hw/dut-image.sh'
DUT_SEL=$DUT labs/hw/bringup-guarded.sh
PROFILE=server1 labs/hw/suite.sh gate
python3 labs/hw/report.py results/run.jsonl --out-dir out
labs/hw/teardown.sh