Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathsh10rt_lan.py
More file actions
680 lines (613 loc) · 32.4 KB
/
Copy pathsh10rt_lan.py
File metadata and controls
680 lines (613 loc) · 32.4 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
#!/usr/bin/env python3
"""Discover SH10RT interfaces, show terminal measurements, inspect state and preview Start."""
from __future__ import annotations
import argparse
from concurrent.futures import ThreadPoolExecutor, as_completed
from datetime import datetime, timezone
import getpass
import ipaddress
import json
import os
import re
import socket
import struct
import sys
import time
import urllib.error
import urllib.parse
import urllib.request
MODEL_CODE = 3599
STOP, START = 206, 207
RUNNING_STATES = (0, 64)
STATES = {0: "Running", 8: "Standby", 16: "Initial Standby", 32: "Startup", 64: "Running", 256: "Fault"}
PRIVATE_NETWORKS = tuple(ipaddress.ip_network(n) for n in
("10.0.0.0/8", "172.16.0.0/12", "192.168.0.0/16"))
class DeviceError(Exception):
"""A failed check or device operation; messages must never contain credentials."""
class UnknownWriteOutcome(DeviceError):
"""A command may have arrived. Never resend it automatically."""
def emit(event, **fields):
print(json.dumps({"time": datetime.now(timezone.utc).isoformat(),
"event": event, **fields}), flush=True)
def lan_ip(value):
try:
address = ipaddress.IPv4Address(value)
except ipaddress.AddressValueError:
raise argparse.ArgumentTypeError("Use a numeric private IPv4 address.") from None
if not any(address in network for network in PRIVATE_NETWORKS):
raise argparse.ArgumentTypeError("Only RFC1918 private LAN addresses are accepted.")
return str(address)
def scan_network(value):
try:
network = ipaddress.IPv4Network(value, strict=True)
except (ValueError, TypeError):
raise argparse.ArgumentTypeError("Use a network CIDR, for example 192.168.1.0/24.") from None
if network.num_addresses > 1024 or not any(network.subnet_of(n) for n in PRIVATE_NETWORKS):
raise argparse.ArgumentTypeError("Select a private LAN subnet of /22 or smaller (at most 1024 addresses).")
return network
def integer(lo, hi):
def parse(value):
try:
result = int(value)
except ValueError:
raise argparse.ArgumentTypeError("Expected an integer.") from None
if not lo <= result <= hi:
raise argparse.ArgumentTypeError(f"Expected {lo} through {hi}.")
return result
return parse
def recv_exact(sock, size):
data = bytearray()
while len(data) < size:
part = sock.recv(size - len(data))
if not part:
raise DeviceError("Connection closed before a complete Modbus response.")
data.extend(part)
return bytes(data)
class Modbus:
transport = "modbus"
def __init__(self, host, unit=1, timeout=3, port=502):
self.host, self.unit, self.timeout, self.port = host, unit, timeout, port
self.transaction = 0
def exchange(self, pdu):
self.transaction = self.transaction % 65535 + 1
packet = struct.pack(">HHHB", self.transaction, 0, len(pdu) + 1, self.unit) + pdu
with socket.create_connection((self.host, self.port), self.timeout) as sock:
sock.settimeout(self.timeout)
sock.sendall(packet)
tid, protocol, length, unit = struct.unpack(">HHHB", recv_exact(sock, 7))
if tid != self.transaction or protocol != 0 or unit != self.unit or not 2 <= length <= 254:
raise DeviceError("Invalid Modbus response header.")
body = recv_exact(sock, length - 1)
if body[0] == (pdu[0] | 0x80):
raise DeviceError(f"Modbus exception {body[1] if len(body) > 1 else 'missing code'}.")
if body[0] != pdu[0]:
raise DeviceError("Unexpected Modbus function code.")
return body
def read(self, address, count, holding=False):
if not 1 <= count <= 125 or not 1 <= address <= 65536 - count + 1:
raise DeviceError("Invalid register range.")
try:
body = self.exchange(struct.pack(">BHH", 3 if holding else 4, address - 1, count))
except OSError:
raise DeviceError("Modbus connection or read timed out/failed.") from None
if len(body) != 2 + count * 2 or body[1] != count * 2:
raise DeviceError("Invalid Modbus register response length.")
return list(struct.unpack(">" + "H" * count, body[2:]))
def identity(self):
words = self.read(4990, 13)
try:
serial = struct.pack(">10H", *words[:10]).rstrip(b"\0 ").decode("ascii")
except (UnicodeError, struct.error):
raise DeviceError("Invalid inverter serial number.") from None
if not re.fullmatch(r"[A-Za-z0-9-]{6,20}", serial):
raise DeviceError("Missing or invalid inverter serial number.")
if words[10] != MODEL_CODE or words[11] != 100:
raise DeviceError("Device is not the supported SH10RT (code 3599, rated 10 kW).")
return serial
def start_once(self):
# The only Modbus write supported: logical holding 13000, wire 12999, Start 207.
request = struct.pack(">BHH", 6, 12999, START)
try:
response = self.exchange(request)
if response != request:
raise DeviceError("Start acknowledgment does not match the command.")
except (DeviceError, OSError):
raise UnknownWriteOutcome("Start outcome unconfirmed. Read status before any manual retry; command was not resent.") from None
def close(self):
pass
class ReadOnlyModbus(Modbus):
def __init__(self, *args, pause=0, stop=None, **kwargs):
super().__init__(*args, **kwargs)
self.pause, self.stop, self.last_request = pause, stop, None
def exchange(self, pdu):
if not pdu or pdu[0] != 4:
raise DeviceError("Values permits input-register reads only.")
if self.last_request is not None:
delay = max(0, self.pause - (time.monotonic() - self.last_request))
if self.stop is not None:
if self.stop.wait(delay):
raise DeviceError("Polling stopped.")
elif delay:
time.sleep(delay)
if self.stop is not None and self.stop.is_set():
raise DeviceError("Polling stopped.")
try:
return super().exchange(pdu)
finally:
self.last_request = time.monotonic()
def number(words, address, scale=1, signed=False, wide=False):
"""Decode documented sentinels before scaling; retain raw words separately."""
value = words.get(address)
if value is None:
return None
bits = 32 if wide else 16
if wide:
high = words.get(address + 1)
if high is None:
return None
value |= high << 16
if value == (2 ** (bits - 1) - 1 if signed else 2**bits - 1):
return None
if signed and value >= 2 ** (bits - 1):
value -= 2**bits
return round(value * scale, 4)
def decode(words):
def n(a, scale=1, signed=False, wide=False):
return number(words, a, scale, signed, wide)
mppts = []
for i in range(2):
voltage, current = n(5011 + 2*i, .1), n(5012 + 2*i, .1)
mppts.append({"name": f"MPPT {i+1}", "voltage_v": voltage,
"current_a": current, "power_w": round(voltage*current, 1)
if voltage is not None and current is not None else None})
flags = [{"register": a, "raw": words[a], "bits": [i for i in range(16) if words[a] & 1 << i]}
for a in range(13050, 13080) if a in words and words[a] not in (0, 65535)]
labels = {(13066, 14): "BMS communication fault", (13070, 5): "Battery voltage unbalance",
(13070, 9): "Cell voltage imbalance", (13072, 9): "Pre-charge failed",
(13072, 10): "Abnormal external power-line status",
(13072, 13): "Voltage sampling fault", (13051, 14): "Meter communication alarm",
(13050, 5): "Parallel communication alarm"}
for flag in flags:
flag["labels"] = [labels.get((flag["register"], bit), f"Unmapped bit {bit}") for bit in flag["bits"]]
meter_phases = [n(a, signed=True, wide=True) for a in (5603, 5605, 5607)]
meter_alarm = words.get(13051)
meter_available = (meter_alarm is not None and meter_alarm != 65535
and not meter_alarm & (1 << 14)
and all(v is not None for v in meter_phases))
net_export = n(13010, signed=True, wide=True) if meter_available else None
comm_status = words.get(13066)
bat_valid = (comm_status is not None and comm_status != 65535
and not comm_status & (1 << 14)
and n(13023, .1) is not None and 0 <= n(13023, .1) <= 100)
def bat(a, scale=1, signed=False):
return n(a, scale, signed) if bat_valid else None
frequency = n(5242, .01)
freq_source = "5242 · 0.01 Hz"
if frequency is None or (frequency != 0 and not 40 <= frequency <= 70):
raw = words.get(5036)
scale = .1 if raw is not None and (raw == 0 or 400 <= raw <= 700) else (
.01 if raw is not None and 4000 <= raw <= 7000 else None)
frequency = round(raw*scale, 2) if scale else None
freq_source = "5036 · legacy scale inferred from value" if scale == .01 else "5036 · legacy 0.1 Hz"
metrics = {
"pv_w": n(5017, wide=True), "ac_w": n(13034, signed=True, wide=True),
"temperature_c": n(5008, .1, True), "frequency_hz": frequency,
"frequency_source": freq_source, "pv_today_kwh": n(13002, .1),
"pv_total_kwh": n(13003, .1, wide=True), "load_w": n(13008, signed=True, wide=True),
"export_w": n(13010, signed=True, wide=True),
"phase_voltage_v": [n(a, .1) for a in (5019, 5020, 5021)],
"phase_current_a": [n(a, .1, True) for a in (13031, 13032, 13033)],
"meter_phase_w": meter_phases if meter_available else [None, None, None],
"meter_phase_sum_w": sum(meter_phases) if meter_available else None,
"meter_grid_import_w": max(0, -net_export) if net_export is not None else None,
"meter_grid_export_w": max(0, net_export) if net_export is not None else None,
"reactive_var": n(5033, signed=True, wide=True), "power_factor": n(5035, .001, True),
"import_today_kwh": n(13036, .1), "export_today_kwh": n(13045, .1),
"battery_voltage_v": bat(13020, .1), "battery_current_a": n(5631, .1, True) if bat_valid else None,
"battery_current_source": "5631 · signed 0.1 A",
"battery_power_w": n(5214, signed=True, wide=True) if bat_valid else None,
"battery_soc_pct": bat(13023, .1), "battery_soh_pct": bat(13024, .1),
"battery_temperature_c": bat(13025, .1, True),
"allowed_charge_a": n(5635) if bat_valid else None,
"allowed_discharge_a": n(5636) if bat_valid else None,
"battery_capacity_kwh": n(5639, .01) if bat_valid else None,
"charge_today_kwh": n(13040, .1), "discharge_today_kwh": n(13026, .1),
"backup_w": n(5726, signed=True, wide=True), "backup_voltage_v": [n(a, .1) for a in (5731, 5732, 5733)],
"backup_current_a": [n(a, .1, True) for a in (5720, 5721, 5722)],
"backup_frequency_hz": n(5734, .01),
}
return {"state": STATES.get(words.get(13000), f"Unknown ({words.get(13000, 'unavailable')})"),
"metrics": metrics, "mppts": mppts, "flags": flags,
"meter_available": meter_available,
"battery_available": bat_valid,
"faults_available": all(a in words and words[a] != 65535 for a in range(13050, 13080))}
class NoRedirect(urllib.request.HTTPRedirectHandler):
def redirect_request(self, req, fp, code, msg, headers, newurl):
raise DeviceError("HTTP redirect refused; verify the device address.")
def http_get(host, path, timeout):
opener = urllib.request.build_opener(urllib.request.ProxyHandler({}), NoRedirect())
try:
with opener.open(f"http://{host}{path}", timeout=timeout) as response:
data = response.read(1024 * 1024 + 1)
except (OSError, urllib.error.URLError):
# urllib exceptions can include a query string containing a session token.
raise DeviceError("Device HTTP request failed.") from None
if len(data) > 1024 * 1024:
raise DeviceError("Device HTTP response exceeds size limit.")
return data
class WiNet(Modbus):
transport = "winet"
def __init__(self, host, username, password, timeout=5):
self.host, self.timeout = host, timeout
self.ws = None
self.token, self.device = "", None
self.admin = False
try:
import websocket
except ImportError:
raise DeviceError("WiNet needs websocket-client: install scripts/requirements.txt.") from None
try:
self.ws = websocket.create_connection(
f"ws://{host}:8082/ws/home/overview", timeout=timeout,
origin=f"http://{host}", http_no_proxy=[host], redirect_limit=0)
connected = self.request({"service": "connect"})
self.token = connected.get("token", "")
if not self.token:
raise DeviceError("WiNet returned no connection token.")
login = self.request({"service": "login", "username": username, "passwd": password})
self.token = login.get("token", "")
self.admin = str(login.get("uid")) == "3"
if not self.token:
raise DeviceError("WiNet returned no authenticated token.")
except Exception as exc:
self.close()
if isinstance(exc, DeviceError):
raise
raise DeviceError("WiNet connection or login failed.") from None
def request(self, payload):
try:
self.ws.send(json.dumps({"lang": "en_us", "token": self.token, **payload}))
deadline = time.monotonic() + self.timeout
while time.monotonic() < deadline:
self.ws.settimeout(max(0.1, deadline - time.monotonic()))
raw = self.ws.recv()
if not raw or len(raw) > 1024 * 1024:
raise DeviceError("WiNet connection closed or response too large.")
data = json.loads(raw)
result = data.get("result_data") or {}
service = result.get("service")
if service == payload["service"] or (not service and data.get("result_code") != 1):
if data.get("result_code") != 1:
raise DeviceError(f"WiNet rejected {payload['service']} request.")
return result
except DeviceError:
raise
except Exception:
raise DeviceError(f"WiNet {payload['service']} response failed or timed out.") from None
raise DeviceError("WiNet response timed out.")
def identity(self):
listing = self.request({"service": "devicelist", "type": "0", "is_check_token": "0"})
# Refuse ambiguous loggers instead of guessing which attached inverter to start.
devices = listing.get("list", [])
if not isinstance(devices, list) or len(devices) != 1:
raise DeviceError("Expected exactly one attached device on this WiNet; inspect this logger manually.")
device = devices[0]
if (not isinstance(device, dict) or not device.get("dev_id")
or str(device.get("dev_code")) != str(MODEL_CODE)
or str(device.get("dev_type")) != "35" or str(device.get("link_status")) != "1"):
raise DeviceError("WiNet has no single online supported SH10RT.")
self.device = device
serial = super().identity()
if serial != device.get("dev_sn"):
raise DeviceError("WiNet device list and inverter serial register disagree.")
return serial
def read(self, address, count, holding=False):
if self.device is None:
raise DeviceError("Identify the WiNet device before reading registers.")
query = urllib.parse.urlencode({"lang": "en_us", "token": self.token,
"dev_id": self.device["dev_id"], "dev_type": self.device["dev_type"],
"dev_code": self.device["dev_code"], "type": "3", "param_addr": address,
"param_num": count, "param_type": "1" if holding else "0"})
try:
result = json.loads(http_get(self.host, "/device/getParam?" + query, self.timeout))
if result.get("result_code") != 1:
raise DeviceError("WiNet register read rejected.")
raw = re.sub(r"\s", "", result["result_data"]["param_value"])
if len(raw) != count * 4 or not re.fullmatch(r"[0-9A-Fa-f]+", raw):
raise DeviceError("WiNet returned invalid register data.")
return [int(raw[i:i + 4], 16) for i in range(0, len(raw), 4)]
except (ValueError, KeyError, TypeError, AttributeError):
raise DeviceError("Invalid WiNet register response.") from None
def start_once(self):
if not self.admin:
raise DeviceError("WiNet Start requires a confirmed maintenance/admin session.")
try:
result = self.request({"service": "param", "dev_code": str(self.device["dev_code"]),
"dev_type": str(self.device["dev_type"]), "devid_array": [str(self.device["dev_id"])],
"type": "3", "count": "1", "list": [{"power_switch": "1"}]})
rows = result.get("list") if isinstance(result, dict) else None
if not isinstance(rows, list) or any(not isinstance(row, dict) for row in rows):
raise DeviceError("Malformed WiNet Boot acknowledgment.")
children = [row for row in rows
if row.get("param_name") == "I18N_COMMON_POWER_ON"]
if not children or any(row.get("result") != 0 for row in children):
raise DeviceError("WiNet Boot not acknowledged.")
except DeviceError:
raise UnknownWriteOutcome("Boot outcome unconfirmed. Read status before any manual retry; command was not resent.") from None
def close(self):
if self.ws is not None:
try:
self.ws.close(timeout=1)
except Exception:
pass
self.ws = None
def grid_frequency(client, legacy_raw):
"""Prefer documented 0.01 Hz data; expose the observed legacy scale inference."""
try:
raw = client.read(5242, 1)[0]
except DeviceError:
raw = None
if raw == 0 or (raw is not None and 4000 <= raw <= 7000):
return {"grid_frequency_Hz": raw / 100, "grid_frequency_register": 5242,
"grid_frequency_raw": raw, "grid_frequency_scale": 0.01,
"grid_frequency_note": "Documented high-precision register."}
# Firmware/interface variants may encode this legacy field at different scales.
# These bounds disambiguate encodings; they are NOT grid protection settings.
scale = 0.1 if legacy_raw == 0 or 400 <= legacy_raw <= 700 else (
0.01 if 4000 <= legacy_raw <= 7000 else None)
return {"grid_frequency_Hz": legacy_raw / (100 if scale == 0.01 else 10) if scale is not None else None,
"grid_frequency_register": 5036, "grid_frequency_raw": legacy_raw,
"grid_frequency_scale": scale,
"grid_frequency_note": (
"High-precision data unavailable; documented 0.1 Hz legacy scale." if scale == 0.1 else
"High-precision data unavailable; 0.01 Hz legacy variant inferred from raw range." if scale == 0.01 else
"Frequency unavailable: unsupported or invalid legacy encoding.")}
VALUE_BLOCKS = ((5008, 29), (13000, 47), (13050, 30), (5214, 2), (5242, 1),
(5631, 1), (5635, 5), (5603, 6), (5720, 8), (5731, 4))
def read_values(client, pause=1.1):
"""Read one identified inverter, with partial failures kept explicit. No holdings or writes."""
serial = client.identity()
words, errors = {}, []
last_keepalive = time.monotonic()
for address, count in VALUE_BLOCKS:
if pause:
time.sleep(pause)
if isinstance(client, WiNet) and time.monotonic() - last_keepalive >= 10:
try:
client.ws.send(json.dumps({"service": "ping", "lang": "en_us", "token": client.token}))
except Exception:
raise DeviceError("WiNet keepalive failed during measurement read.") from None
last_keepalive = time.monotonic()
try:
raw = client.read(address, count)
if len(raw) != count:
raise DeviceError("Incomplete register block.")
words.update(zip(range(address, address + count), raw))
except DeviceError as exc:
errors.append({"register": address, "count": count, "message": str(exc)})
if not words:
raise DeviceError("Identity verified, but all measurement blocks failed.")
return {"host": client.host, "transport": client.transport, "serial": serial,
"model": "SH10RT", "sampled_at": datetime.now(timezone.utc).isoformat(),
"partial": bool(errors), "errors": errors, **decode(words)}
def print_values(sample):
def formatted(value):
if value is None:
return "unavailable"
if isinstance(value, list):
return " / ".join(formatted(item) for item in value)
return f"{value:g}" if isinstance(value, (int, float)) else str(value)
print(f"\n{sample['model']} {sample['serial']} @ {sample['host']} ({sample['transport']})")
print(f"Sample: {sample['sampled_at']} | State: {sample['state']}"
+ (" | Partial read" if sample['partial'] else ""))
print("\nPV tracker Voltage (V) Current (A) Calculated power (W)")
for tracker in sample['mppts']:
print(f"{tracker['name']:<14} {formatted(tracker['voltage_v']):<14}"
f" {formatted(tracker['current_a']):<14} {formatted(tracker['power_w'])}")
print("\nMeasurements (phase arrays: A / B / C):")
for key, value in sample['metrics'].items():
print(f" {key:<28} {formatted(value)}")
print(f"\nBattery telemetry available: {sample['battery_available']}"
f" | Meter available: {sample['meter_available']}")
print("Fault/alarm words" + (":" if sample['faults_available'] else " (incomplete/unavailable):"))
for flag in sample['flags']:
print(f" Input {flag['register']} = 0x{flag['raw']:04X}: " + "; ".join(flag['labels']))
if not sample['flags']:
print(" None set." if sample['faults_available'] else " No reliable all-clear reading.")
for error in sample['errors']:
print(f" Read error {error['register']}/{error['count']}: {error['message']}")
def values_command(args):
"""Inspect each explicitly selected host once; a failure does not hide other devices."""
failed = False
password = None
if args.transport == "winet":
password = os.environ.get("SH10RT_PASSWORD")
if password is None:
if not sys.stdin.isatty():
raise DeviceError("WiNet password required: use an interactive terminal or SH10RT_PASSWORD.")
password = getpass.getpass("WiNet password: ")
for host in dict.fromkeys(args.host):
client = None
try:
client = (ReadOnlyModbus(host, args.unit, args.timeout) if args.transport == "modbus"
else WiNet(host, args.username, password, args.timeout))
sample = read_values(client)
failed = failed or sample['partial']
if args.json:
emit("values", **sample)
else:
print_values(sample)
except DeviceError as exc:
failed = True
if args.json:
emit("error", host=host, message=str(exc))
else:
print(f"{host}: {exc}", file=sys.stderr)
finally:
if client is not None:
client.close()
return 2 if failed else 0
def snapshot(client):
serial = client.identity()
state = client.read(13000, 37)
start_stop = client.read(13000, 1, holding=True)[0]
alarms = client.read(13050, 30)
measurements = client.read(5008, 29)
words = dict(zip(range(5008, 5037), measurements))
words.update(zip(range(13000, 13037), state))
return {"host": client.host, "transport": client.transport, "serial": serial,
"model": "SH10RT", "state": state[0], "state_name": STATES.get(state[0], "Unknown"),
"start_stop": start_stop, "start_stop_name": {STOP: "Stop", START: "Start"}.get(start_stop, "Unknown"),
"active_power_W": number(words, 13034, signed=True, wide=True),
"pv_voltage_V": [number(words, address, .1) for address in (5011, 5013)],
"grid_voltage_V": [number(words, address, .1) for address in (5019, 5020, 5021)],
**grid_frequency(client, measurements[28]),
"temperature_C": number(words, 5008, .1, signed=True),
"alarms": [{"register": 13050 + i, "value": value} for i, value in enumerate(alarms) if value],
"meter_communication_alarm": bool(alarms[1] & 0x4000),
"parallel_communication_alarm": bool(alarms[0] & 0x20)}
def start_device(client, expected_serial, execute=False, wait=0, poll=10):
before = snapshot(client)
emit("preflight", **before)
if before["serial"] != expected_serial:
raise DeviceError("Serial mismatch: no command sent.")
if before["alarms"]:
raise DeviceError("Current fault/alarm bits are set. Resolve them before using automated Start.")
if before["start_stop"] == START:
emit("no_change", reason="Start is already enabled; no command sent.")
if wait:
return observe(client, expected_serial, wait, poll)
return 0
if before["start_stop"] != STOP or before["state"] not in (8, 16):
raise DeviceError("Start is supported only for confirmed Stop with Standby or Initial Standby.")
if not execute:
emit("dry_run", serial=expected_serial, action="Start once", execute=False)
return 0
# Re-read all preconditions, including identity, immediately before the only write.
final = snapshot(client)
if (final["serial"] != expected_serial or final["start_stop"] != STOP
or final["state"] not in (8, 16) or final["alarms"]):
raise DeviceError("Device identity or start conditions changed; no command sent.")
client.start_once()
emit("start_acknowledged", serial=expected_serial, commands_sent=1)
# Verify once. A failure here must never cause another write.
try:
after = snapshot(client)
if after["serial"] != expected_serial or after["start_stop"] != START:
raise DeviceError("Start read-back mismatch.")
except DeviceError:
raise UnknownWriteOutcome("Command acknowledged, but read-back unconfirmed. Inspect status; do not automatically resend.") from None
emit("read_back", **after)
if wait:
return observe(client, expected_serial, wait, poll)
emit("verification_limit", message="Start setting verified; sustained generation has not been verified. Use --wait 330.")
return 0
def observe(client, serial, wait, poll):
deadline = time.monotonic() + wait
consecutive = 0
while True:
state = snapshot(client)
if state["serial"] != serial:
raise DeviceError("Device identity changed during observation.")
emit("observation", **state)
healthy = (state["state"] in RUNNING_STATES and state["active_power_W"] is not None
and state["active_power_W"] > 0 and not state["alarms"])
consecutive = consecutive + 1 if healthy else 0
if consecutive >= 2:
emit("generation_verified", serial=serial, consecutive_samples=consecutive)
return 0
remaining = deadline - time.monotonic()
if remaining <= 0:
emit("not_yet_generating", message="Observation ended without two healthy generating samples; no command repeated.")
return 3
# Keep a WiNet session alive while waiting without requiring a background thread.
time.sleep(min(poll, remaining, 10))
if isinstance(client, WiNet):
try:
client.ws.send(json.dumps({"service": "ping", "lang": "en_us", "token": client.token}))
except Exception:
raise DeviceError("WiNet keepalive failed; inspect status before retrying.") from None
def discover_host(host, unit, timeout):
found = []
native = Modbus(host, unit, timeout)
try:
serial = native.identity()
found.append({"host": host, "transport": "modbus", "serial": serial, "model": "SH10RT", "unit": unit})
except DeviceError:
pass
try:
page = http_get(host, "/", timeout).decode("utf-8", errors="replace")
if re.search(r"<title[^>]*>[^<]*WiNet[^<]*</title>", page, re.I):
found.append({"host": host, "transport": "winet", "identity_verified": False,
"next_step": "Use status with maintenance login to identify the attached inverter."})
except DeviceError:
pass
return found
def make_parser():
parser = argparse.ArgumentParser(description=__doc__)
subs = parser.add_subparsers(dest="command", required=True)
scan = subs.add_parser("scan", help="Read-only discovery; WiNet detection does not send credentials.")
scan.add_argument("--network", type=scan_network, required=True)
scan.add_argument("--workers", type=integer(1, 32), default=16)
scan.add_argument("--timeout", type=integer(1, 10), default=1)
scan.add_argument("--unit", type=integer(1, 247), default=1)
for command in ("status", "start", "values"):
sub = subs.add_parser(command)
sub.add_argument("--host", type=lan_ip, required=True,
**({"action": "append", "help": "Repeat for multiple inverter interfaces."}
if command == "values" else {}))
sub.add_argument("--transport", choices=("modbus", "winet"), required=True)
sub.add_argument("--unit", type=integer(1, 247), default=1, help="Native Modbus unit ID; ignored for WiNet.")
sub.add_argument("--username", default="admin", help="WiNet account; password is prompted, or read from SH10RT_PASSWORD.")
sub.add_argument("--timeout", type=integer(1, 30), default=5)
if command == "values":
sub.add_argument("--json", action="store_true", help="Emit JSON Lines instead of a terminal report.")
if command == "start":
sub.add_argument("--serial", required=True, help="Exact serial number, independently checked against the intended device.")
sub.add_argument("--execute", action="store_true", help="Actually send one Start command. Without this flag: read-only preview.")
sub.add_argument("--wait", type=integer(0, 1200), default=0, metavar="SECONDS")
return parser
def main(argv=None):
args = make_parser().parse_args(argv)
client = None
try:
if args.command == "scan":
matches = []
with ThreadPoolExecutor(max_workers=args.workers) as pool:
jobs = [pool.submit(discover_host, str(ip), args.unit, args.timeout) for ip in args.network.hosts()]
for job in as_completed(jobs):
for row in job.result():
matches.append(row)
emit("discovered", **row)
emit("scan_complete", interfaces=len(matches), network=str(args.network),
note="No writes or login attempts. Unreachable or unsupported devices may not be found.")
return 0 if matches else 4
if args.command == "values":
return values_command(args)
if args.transport == "modbus":
client = Modbus(args.host, args.unit, args.timeout)
else:
password = os.environ.get("SH10RT_PASSWORD")
if password is None:
if not sys.stdin.isatty():
raise DeviceError("WiNet password required: use an interactive terminal or SH10RT_PASSWORD.")
password = getpass.getpass("WiNet password: ")
client = WiNet(args.host, args.username, password, args.timeout)
if args.command == "status":
emit("status", **snapshot(client))
return 0
return start_device(client, args.serial, args.execute, args.wait)
except UnknownWriteOutcome as exc:
emit("write_outcome_unconfirmed", message=str(exc))
return 5
except (DeviceError, OSError) as exc:
emit("error", message=str(exc) if isinstance(exc, DeviceError) else "Local/network I/O failed.")
return 2
except KeyboardInterrupt:
emit("interrupted", message="No automatic retry. A previously sent command may still take effect; inspect status.")
return 130
finally:
if client is not None:
client.close()
if __name__ == "__main__":